Related papers: Cryogenic avalanche detectors based on gas electro…
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting…
A novel concept of optical signal recording in two-phase avalanche detectors, with Geiger-mode Avalanche Photodiodes (G-APD) is described. Avalanche-scintillation photons were measured in a thick Gas Electron Multiplier (THGEM) in view of…
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment…
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an…
Micro-Pattern Gas Detectors (MPGDs) represent a category of gaseous ionization detectors that utilize microelectronics. They feature a remarkably small distance between the high potential difference anode and cathode electrodes and are…
One of the main features of two-phase detectors with electroluminescence (EL) gap being developed in our laboratory for dark matter search is the extensive use of THGEMs (Thick Gas Electron Multipliers). In various versions of the detector,…
Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…
The performance of triple-GEM detectors in He+N2 gas mixtures is studied in the range of 1-10 atm. The results obtained are relevant in the field of minimization of ionic space-charge effect in the TPC and neutron detection.
The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron…
Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI…
A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…
Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…
We study the performance of single- and double- THick Gas Electron Multiplier (THGEM) detectors in pure Hydrogen and Deuterium at low pressures, in the range of 100-450 Torr. The effect of the pressure on the maximum achievable gain,…
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the…
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…
At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…