Related papers: New Limits to the Drift of Fundamental Constants f…
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating…
Precision comparisons of different atomic frequency standards over a period of a few years can be used for a sensitive search for temporal variations of fundamental constants. We present recent frequency measurements of the 688 THz…
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency…
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These…
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent…
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or…
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $\alpha$ and the…
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave…
The $^1\mathrm{S}_0$-$^3\mathrm{P}_0$ clock transition frequency $\nu_\text{Sr}$ in neutral $^{87}$Sr has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years.…
We used a Cs atomic fountain frequency standard to measure the Stark shift on the ground state hyperfine transiton frequency in cesium (9.2 GHz) due to the electric field generated by the blackbody radiation. The measures relative shift at…
An optical measurement of the 2S hyperfine interval in atomic hydrogen using two-photon spectroscopy of the 1S-2S transition gives a value of 177 556 834.3(6.7) Hz. The uncertainty is 2.4 times smaller than achieved by our group in 2003 and…
Using the Dirac equation, radiative corrections and finite nuclear size and mass corrections, we calculate the $1s$-$2s$ quantum transition frequency $f_{1s,2s}$ of hydrogen and its uncertainty due to the uncertainties $\delta m_e, \delta…
We report on new tests that improve our previous (2009-2010) estimates of the electron-to-proton mass ratio variation, mu = m_e/m_p. Subsequent observations (2011-2013) at the Effelsberg 100-m telescope of a sample of eight molecular cores…
In this Comment, we reanalyze the experiments on the collision frequency shift of the b-c and a-d hyperfine transitions in three-dimensional atomic hydrogen in the presence of, respectively, a and b-state atoms. Accurate consideration of…
We present a measurement of the hydrogen $2$S$_{1/2}-8$D$_{5/2}$ transition performed with a cryogenic atomic beam. The measured resonance frequency is $\nu=770649561570.9(2.0)$ kHz, which corresponds to a relative uncertainty of…
We have observed the cold collision frequency shift of the 1S-2S transition in trapped spin-polarized atomic hydrogen. We find $\Delta \nu_{1S-2S} = -3.8(8)\times 10^{-10} n Hz cm^3$, where $n$ is the sample density. From this we derive the…
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische…
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the…
We have performed calculations of the size of the frequency shift induced by a static electric field on the clock transition frequencies of the hyperfine splitting in Yb+, Rb, Cs, Ba+, and Hg+. The calculations are used to find the…
Over a period of eight months, we have monitored transition frequencies between nearly degenerate, opposite-parity levels in two isotopes of atomic dysprosium (Dy). These transition frequencies are highly sensitive to temporal variation of…