English
Related papers

Related papers: CMS barrel Resistive Plate Chambers - tests and re…

200 papers

During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…

Instrumentation and Detectors · Physics 2020-07-24 Priyanka Kumari

We report on the first steps in the development of a small-size muon telescope based on glass Resistive Plate Chambers with small active area ($16\times 16~{\rm cm}^2$). The long-term goal of this project is to focus on applications of…

Instrumentation and Detectors · Physics 2018-12-19 Sophie Wuyckens , Andrea Giammanco , Pavel Demin , Eduardo Cortina Gil

The CMS experiment at the LHC includes a hybrid silicon pixel detector for the reconstruction of charged tracks and of the interaction vertices. The detector is made of three barrel layers and two disks at each end of the barrel. Detector…

Instrumentation and Detectors · Physics 2007-10-29 Vincenzo Chiochia

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…

Research on a large-area, cost-effective Muon Telescope Detector has been carried out for RHIC and for next generation detectors at future QCD Lab. We utilize state-of-the-art multi-gap resistive plate chambers with large modules and long…

Nuclear Experiment · Physics 2019-08-13 Lijuan Ruan

The use of conventional imaging techniques becomes problematic when faced with challenging logistics and confined environments. In particular, such scenarios are not unusual in the field of archaeological and mining explorations as well as…

Instrumentation and Detectors · Physics 2022-02-03 S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , R. Karnam , M. Moussawi , A. Samalan , M. Tytgat

In the High Luminosity Large Hadron Collider (HL-LHC) program, during the next years, the instantaneous luminosity will increase up to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$ which means a factor five higher than the nominal LHC. In that…

Instrumentation and Detectors · Physics 2021-11-30 R. Aly

The muon system of the CMS experiment is expected to upgrade all of its subdetectors for the Phase-2 of the Large Hadron Collider (LHC) that will begin in 2029. The upgrade plans for drift tubes (DTs), cathode strip chambers (CSCs) and…

Instrumentation and Detectors · Physics 2023-12-19 Antonello Pellecchia

The forward muon spectrometer of ALICE (A Large Ion Collider Experiment) is equipped with a trigger system made of four planes of Resistive Plate Chambers (RPC), arranged in two stations with two planes each, for a total area of about 140…

Instrumentation and Detectors · Physics 2012-11-09 Francesco Bossù , Martino Gagliardi , Massimiliano Marchisone , ALICE Collaboration

Muon tomography or muography is an emerging imaging technique that uses cosmogenic muons as the radiation source. Due to its diverse range of applications and the use of natural radiation, muography is being applied across many fields such…

Instrumentation and Detectors · Physics 2022-02-02 R. M. I. D Gamage , S. Basnet , E. Cortina Gil , P. Demin , A. Giammanco , R. Karnam , M. Moussawi , M. Tytgat , .

The ALICE muon trigger (MTR) system consists of 72 Resistive Plate Chamber (RPC) detectors arranged in two stations, each composed of two planes with 18 RPCs per plane. The detectors are operated in maxi-avalanche mode using a mixture of…

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector…

Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field…

Instrumentation and Detectors · Physics 2012-08-27 The CMS Collaboration

The CMS detector is under construction for imminent operation at the Large Hadron Collider at CERN near Geneva, Switzerland. The installation and commissioning is performed in a surface hall. Thereafter, all the main heavy elements of the…

Instrumentation and Detectors · Physics 2008-05-14 Tim Christiansen

A water-based cooling system is being investigated to meet the cooling requirement of the Gas Electron Multiplier (GEM) based Muon Chamber (MuCh) detector system of the Compressed Baryonic Matter (CBM) experiment at GSI, Germany. The system…

The Compact Muon Solenoid (CMS) calorimeter regional trigger system is designed to detect signatures of isolated and non-isolated electrons/photons, jets, ?-leptons, and missing and total transverse energy using a deadtimeless pipelined…

High Energy Physics - Experiment · Physics 2007-05-23 P. Chumney , S. Dasu , J. Lackey , M. Jaworski , P. Robl , W. H. Smith

Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…

Instrumentation and Detectors · Physics 2016-11-23 I. Deppner , N. Herrmann , J. Frühauf , M. Kiš , P. Lyu , P. -A. Loizeau , L. Shi , C. Simon , Y. Wang , B. Xie

Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized…

Instrumentation and Detectors · Physics 2022-01-05 L. Mao , F. Lagarde , J. Guo , X. Wang , J. Li , Q. Shen , J. Zhu , H. Yang

CMS experiment constructed the fourth Resistive Plate Chamber (RPC) trigger station composed of 144 RPCs to enhance the high momentum muon trigger efficiency at both endcap regions. All new CMS endcap RPC gaps are produced in accordance…

Instrumentation and Detectors · Physics 2015-06-22 Sung Keun Park , Min Ho Kang , Kyong Sei Lee