English
Related papers

Related papers: Performance of a micro-TPC for a time-resolved neu…

200 papers

A Micromegas-based active-target detector named SAT-TPC (Saha Active Target TPC) has been designed and fabricated at the Saha Institute of Nuclear Physics. The SAT-TPC was tested with Ar-CO2 (90:10) and Ar-iC4H10 (95:5) at atmospheric…

Instrumentation and Detectors · Physics 2026-05-22 Pralay Kumar Das , Nayana Majumdar , Supratik Mukhopadhyay

We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5 GeV electron beam at DESY. Different GEM orientations and geometries were…

Instrumentation and Detectors · Physics 2009-02-02 U. Renz

Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laboratories. A gaseous time projection chamber (TPC) can be used for…

Instrumentation and Detectors · Physics 2022-08-08 Haiyan Du , Chengbo Du , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Wenming Zhang , Li Zhao , Jifang Zhou

We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured…

This paper presents the experimental results of $17~MeV$ proton irradiation on a $60~GHz$ low power, half-duplex transceiver (TRX) chip implemented in $65~nm$ CMOS technology. It supports short range point-to-point data rate up to $6~Gbps$…

We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved…

Instrumentation and Detectors · Physics 2024-01-31 J. Balajthy , P. Marleau , M. Sweany

Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $\mu$m has been achieved, which is equivalent to an UCN energy resolution below…

A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification…

Instrumentation and Detectors · Physics 2018-08-23 C. Ligtenberg , K. Heijhoff , Y. Bilevych , K. Desch , H. van der Graaf , F. Hartjes , J. Kaminski , P. M. Kluit , G. Raven , T. Schiffer , J. Timmermans

The ATLAS Transition Radiation Tracker (TRT) is the outermost of the three sub-systems of the ATLAS Inner Detector at the Large Hadron Collider at CERN. In addition to its tracking capabilities, the TRT provides particle identification…

Instrumentation and Detectors · Physics 2019-08-13 E. Hines

A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…

Instrumentation and Detectors · Physics 2014-11-24 T. J. Langford , C. D. Bass , E. J. Beise , H. Breuer , D. K. Erwin , C. R. Heimbach , J. S. Nico

The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…

Instrumentation and Detectors · Physics 2008-11-26 M. S. Dixit , A. Rankin

A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…

Instrumentation and Detectors · Physics 2010-02-03 S. Kawasaki , G. Ichikawa , M. Hino , Y. Kamiya , M. Kitaguchi , S. Komamiya , T. Sanuki , S. Sonoda

We constructed a new time-of-flight (TOF) detector consisting of resistive plate chambers (RPCs) to measure particle energy in the BGOegg experiment. The BGOegg-RPC has a unique feature which enables us to cover a large area with a small…

Instrumentation and Detectors · Physics 2016-12-21 N. Tomida , N. Tran , M. Niiyama , H. Ohnishi , N. Muramatsu

The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the…

A neutron time projection chamber can locate the approximate direction of a neutron hot spot with high efficiency and a 4{\pi} field of view. The angular resolution can be significantly improved by adding several plastic scintillation…

Instrumentation and Detectors · Physics 2019-07-11 Yidong Fu , Yang Tian , Yulan Li , Yigang Yang , Yiming Cai , Jian Yang , Jin Li

In this paper we present the results from the measurements made with the MUNU TPC at 1bar pressure of CF4 in the energy region below 1 MeV. Electron events down to 80 keV are successfully measured. The electron energy and direction are…

We report about a nuclear track imaging system which is designed to study in detail the ionization topology of charged particle tracks in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with…

Instrumentation and Detectors · Physics 2007-05-23 U. Titt , A. Breskin , R. Chechik , V. Dangendorf , H. Schmidt-Boecking , H. Schuhmacher

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3$\times$1$\times$1~m$^3$) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of…

Instrumentation and Detectors · Physics 2021-04-19 WA105 collaboration

The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $\pi^+ \to e^+\nu_e(\gamma)$, aka $\pi_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number…

Instrumentation and Detectors · Physics 2021-07-07 C. J. Glaser , D. Pocanic , A. van der Schaaf , V. A. Baranov , N. V. Khomutov , N. P. Kravchuk , N. A. Kuchinsky