Related papers: A Textured Silicon Calorimetric Light Detector
Silicon photodetectors operating at near-infrared wavelengths with high-speed and high sensitivity are becoming critical for emerging applications, such as Light Detection and Ranging Systems (LIDAR), quantum communications, and medical…
Resistance thermometry provides a time-tested method for taking temperature measurements. However, fundamental limits to resistance-based approaches has produced considerable interest in developing photonic temperature sensors to leverage…
A cryogenic detector system based on two 3.3 kg high-purity CsI crystals was developed and characterized at approximately 95 K. Each wedge-shaped crystal was coupled to dual-ended 3-inch photomultiplier tubes (PMTs) for scintillation…
The Cryogenic Rare Event Search with Superconducting Thermometers Phase II (CRESST-II) at the L.N.G.S in Italy is searching for Dark Matter using low-temperature calorimeters. These detectors allow to discriminate different particles by…
Future cryogenic experiments searching for rare events require reliable, efficient and robust techniques for the detection of photons at temperatures well below that to which low-temperature photomultipliers (PMT) were characterised.…
Spin-active colour centres in 4H silicon carbide are promising candidates as building blocks for quantum information applications. To increase the photon count rate of the emitters at low temperatures, the colour centres must be integrated…
The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…
A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of…
A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…
Silicon is an extremely attractive material platform for integrated optics at telecommunications wavelengths, particularly for integration with CMOS circuits. Developing detectors and electrically pumped lasers at telecom wavelengths are…
We exploit millimeter wave technology to measure the reflection and transmission response of random dielectric media. Our samples are easily constructed from random stacks of identical, sub-wavelength quartz and Teflon wafers. The…
Photon number resolving detectors play a central role in quantum optics. A key challenge in resolving the number of absorbed photons in the microwave frequency range is finding a suitable material that provides not only an appropriate band…
Although inorganic scintillators are widely used in the design of electromagnetic calorimeters for high-energy physics and astrophysics, their crystalline nature and, hence, their lattice orientation are generally neglected in the detector…
A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the…
This article reports on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises…
We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…
We measure and explain scintillator non-proportionality and gamma quenching of CaWO4 at low energies and low temperatures. Phonons that are created following an interaction in the scintillating crystal at temperatures of 15mK are used for a…
We investigated STM-induced chlorine desorption and lithographic patterning of Cl-terminated Si(100)-(2x1) surfaces at sample temperatures from 4 K to 600 K. STM lithography has previously focused on hydrogen-based chemistry for donor…
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted…
Calorimeters are a crucial component in modern particle detectors. They are responsible for providing accurate energy measurements of particles produced in high-energy collisions. The demanding requirements set for next-generation collider…