Related papers: Low noise temperature control : application to an …
We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $\Omega$ down to 0.2 m$\mathrm{\Omega}$. This results in…
Dedicated read-out electronics was developed for low impedance resistive thermometers. Using this high performance temperature controller, the temperature dependence of the excess noise of a YBa2Cu307-d (YBCO) sample in the superconducting…
In electrically substituted radiometers, the ultra low noise control of the temperature is required. In this framework, we present results dedicated to the temperature regulation of copper plates, 3 cm diameter and 1 mm thick, using…
A simple and low cost apparatus has been designed and built to measure the electrical resistivity, ($\rho$), of metal and semiconductors in 300-620 K temperature range. The present design is suitable to do measurement on rectangular bar…
We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission…
An apparatus was developed to obtain, for the first time, 2D maps of the surface resistance of the inner surface of an operating superconducting radio-frequency niobium cavity by a low-temperature laser scanning microscopy technique. This…
We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…
We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication…
We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a…
We describe a compact calorimeter that opens ultra-low temperature heat capacity studies of small metal crystals in moderate magnetic fields. The performance is demonstrated on the canonical heavy Fermion metal YbRh2Si2. Thermometry is…
We report on the development of a sub-kelvin, single-crystal silicon Fabry-Perot cavity. Operating such a cavity below 1~K should reduce the thermal noise limit of the cavity, and by this way address the current limitations of ultrastable…
Scaling up trapped-ion quantum computers requires new trap materials to be explored. Here, we present experiments with a surface ion trap made from the high-temperature superconductor YBCO, a promising material for future trap designs. We…
We develop a high frequency, wide bandwidth radiometer operating at room temperature, which augments the traditional technique of Johnson noise thermometry for nanoscale thermal transport studies. Employing low noise amplifiers and an…
We have developed a nuclear magnetic resonance spectrometer with a series tuned input circuit for measurements on samples at millikelvin temperatures based on an integrated two-stage superconducting quantum interference device current…
This paper describes the design, implementation, and verification of a test-bed for determining the noise temperature of radio antennas operating between 400-800MHz. The requirements for this test-bed were driven by the HIRAX experiment,…
We develop and demonstrate a compact (less than $6$ mL) portable Fabry-P\'{e}rot optical reference cavity. A laser locked to the cavity is thermal noise limited at $2\times10^{-14}$ fractional frequency stability. Broadband feedback control…
Low-noise amplifiers are of great importance in the field of quantum technologies. We study a thermally driven parametric amplifier based on a superconductor-insulator-graphene-insulator-superconductor (SIGIS) junction coupled to a…
High-resolution temperature measurements are required in the LTP, i.e., 10 uK/sqrt(Hz) from 1 mHz to 30 mHz. This has been already accomplished with thermistors and a suitable low noise electronics. However, the frequency range of interest…
We report on the development of an induction based low temperature high frequency ac susceptometer capable of measuring at frequencies up to 3.5 MHz and at temperatures between 2 K and 300 K. Careful balancing of the detection coils and…
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described…