English
Related papers

Related papers: Beyond the RICH: Innovative Photosensitive Gaseous…

200 papers

The challenge of next generation datacom and telecom communication is to increase the available bandwidth while reducing the size, cost and power consumption of photonic integrated circuits. Silicon (Si) photonics has emerged as a viable…

In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive…

Instrumentation and Detectors · Physics 2015-06-04 P. Fonte , E. Nappi , P. Martinengo , R. Oliveira , V. Peskov F. Pietropaolo , P. Picchi

The visualization of pure phase objects by wavefront sensing has important applications ranging from surface profiling to biomedical microscopy, and generally requires bulky and complicated setups involving optical spatial filtering,…

Optics · Physics 2023-08-29 Jianing Liu , Hao Wang , Yuyu Li , Lei Tian , Roberto Paiella

Hyperspectroscopy is a new method of surface image taking, providing simultaneously high position and spectral resolutions which allow one to make some conclusions about chemical compositions of the surfaces. We are now studying…

Instrumentation and Detectors · Physics 2016-11-18 I. Rodionov , J-M. Bidault , I. Crotty , P. Fonte , F. Galy , V. Peskov , O. Zanette

The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a…

Graphene has emerged as a novel platform for opto-electronic applications and photodetector, but the inefficient conversion from light to current has so far been an important roadblock. The main challenge has been to increase the light…

We have developed a cost effective technology for manufacturing various layouts of micropattern gaseous detectors for a wide range of applications. Such devices feature resistive electrodes interfaced to a network of thin readout…

Instrumentation and Detectors · Physics 2015-06-15 V. Peskov , A. Di Mauroa , P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , P. Pietropaolo , P. Picchi

Detecting light is fundamental to all optical experiments and applications. At the single photon level, the quantised nature of light requires specialised detectors, which typically saturate for more than one photon, rendering the…

Here we propose a new design paradigm for a superconducting nanowire single photon detector that uses a multi-layer architecture that places the electric leads beneath the nanowires. This allows for a very large number of detector elements,…

Optics · Physics 2015-06-04 A. Matthew Smith

The electronic properties of graphene are unique and are attracting increased attention to this novel 2-dimensional system. Its photonic properties are not less impressive. For example, this single atomic layer absorbs through direct…

Materials Science · Physics 2009-12-25 Fengnian Xia , Thomas Mueller , Yu-ming Lin , Alberto Valdes-Garcia , Phaedon Avouris

Single photon detectors are fundamental tools of investigation in quantum optics and play a central role in measurement theory and quantum informatics. Photodetectors based on different technologies exist at optical frequencies and much…

Quantum Physics · Physics 2016-10-19 Sankar Raman Sathyamoorthy , Thomas M. Stace , Göran Johansson

We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte , M. Danielsson , C. Iacobaeus , J. Ostling , M. Wallmark

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…

Instrumentation and Detectors · Physics 2011-07-19 M. S. Dixit , J. Dubeau , J. -P. Martin , K. Sachs

Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in a CMOS compatible InGrid technology, which allows to post-process it…

Instrumentation and Detectors · Physics 2015-05-18 Joost Melai , Alexey Lyashenko , Amos Breskin , Harry van der Graaf , Jan Timmermans , Jan Visschers , Cora Salm , Jurriaan Schmitz

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

Instrumentation and Detectors · Physics 2020-01-29 A. Rocchi , R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento

Photographic emulsion is a particle tracking device which features the best spatial resolution among particle detectors. For certain applications, for example muon radiography, large-scale detectors are required. Therefore, a huge surface…

Instrumentation and Detectors · Physics 2016-03-07 T. Ariga , A. Ariga , K. Kuwabara , K. Morishima , M. Moto , A. Nishio , P. Scampoli , M. Vladymyrov

A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors…

Instrumentation and Detectors · Physics 2011-08-31 P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , P. Pietropaolo , P. Picchi

Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI…

Instrumentation and Detectors · Physics 2015-09-02 B. Lopez Paredes , C. D. R. Azevedo , S. Paganis , A. L. M. Silva , N. J. C. Spooner , J. F. C. A. Veloso

In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte

Gigahertz (GHz) imaging using hard X-rays ($\gtrsim$ 10 keV) can be useful to high-temperature plasma experiments, as well as research using coherent photons from synchrotron radiation and X-ray free electron lasers. GHz framing rate can be…

Instrumentation and Detectors · Physics 2023-08-22 Zhehui Wang , C. L. Morris , J. S. Kapustinsky , K. Kwiatkowski , S. -N. Luo