English
Related papers

Related papers: Scintillator-photodiode type detectors for multi-e…

200 papers

Inorganic scintillators are widely used for scientific, industrial and medical applications. The development of 3D printing with inorganic scintillators would allow fast creation of detector prototypes for registration of ionizing…

Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres…

We report on a new photon-counting detector possessing unprecedented spatial resolution, moderate spectral resolution and high background-rejection capability for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and…

Astrophysics · Physics 2009-11-10 E. Miyata , K. Tamura

We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved…

Instrumentation and Detectors · Physics 2024-01-31 J. Balajthy , P. Marleau , M. Sweany

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…

Instrumentation and Detectors · Physics 2017-11-06 J. Antunes , J. Machado , L. Peralta , N. Matela

Introduction: Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSD) promise high spatial resolution and real-time dosimetry with minimum perturbation of the…

Scintillators convert ionizing radiation into visible photons, enabling applications from cosmic ray detection to medical imaging. Two independent strategies for improving scintillator performance via nanoscale patterning have recently been…

Scintillators with pulse-shape discrimination (PSD) capability are of great interest to many fields in the scientific community. The ability to discern a gamma ray from a neutron using PSD varies between different types of scintillator…

Instrumentation and Detectors · Physics 2021-11-18 M. I. Pinilla-Orjuela , K. E. Mesick , P. F. Bloser , J. R. Tutt

For radiography applications using fast neutrons simultaneously with gammas we have developed a detector with 16 stilbene crystals in a 4$\times$4 2D array with a 5~mm pitch and a depth of 25~mm. The crystal array is read out by Silicon…

Instrumentation and Detectors · Physics 2021-03-24 R. Adams , C. Günther , N. Höflich , O. Pooth

The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…

Instrumentation and Detectors · Physics 2007-05-23 S. V. Naydenov , V. D. Ryzhikov

Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by R\"ontgen, RadIT now come in many modalities such as…

Photon Number Resolving Detectors (PNRDs) are devices capable of measuring the number of photons present in an incident optical beam, enabling light sources to be measured and characterized at the quantum level. In this paper, we explore…

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…

Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of…

Instrumentation and Detectors · Physics 2025-05-13 M. Bonesini

We present a scintillator based detector able to measure both spatial and energy information at High repetition rate (HRR) with a relatively simple design. It has been built at the Center of Pulsed Laser (CLPU) in Salamanca and tested in…

Instrumentation and Detectors · Physics 2019-04-03 M. Huault , D. De Luis , J. Alpinaniz , M. De Marco , J. A. Perez-Hernandez , N. Gordillo Garcia , C. Gutierrez , L. Roso , G. Gatti , L. Volpe

We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…

Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications.…

Instrumentation and Detectors · Physics 2018-08-29 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith