Related papers: Photon sandwich detectors with WLS fiber readout
This work presents the design and performance study of compact strips of plastic scintillator with WLS-fiber readout in a dimension of 0.1 * 0.02 * 2 m3, which evaluates as a candidate for cosmic-ray muon detector for JUNO-TAO. The strips…
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of…
We present light yield and uniformity measurements of square and hexagonal tiles read out with silicon photomultipliers via a Y11 wavelength-shifting fiber or directly from the side or from the center at the top face. All tiles are 3~mm…
A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…
The Atomic Spectroscopy and Collisions Using Slow Antiprotons (ASACUSA) experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton…
This note describes a prototype particle tracking detector constructed with 1 mm plastic scintillating fibres with a 64 channel Hamamatsu H8500 flat-panel multi-anode photomultiplier readout. Cosmic ray tracks from an array of 11 gas-filled…
We report results of characterizing the response and light transport of wavelength-shifting (WLS) and scintillating-wavelength-shifting (Sci-WLS) fibers under irradiation by radioactive $\alpha$, $\beta$, and $\gamma$ sources. Light yield…
Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam…
A tracking detector based on two meters long scintillating fibers read out by silicon photomultipliers (SiPM) is being developed for the Kaos spectrometer at the Mainz Microtron MAMI. Results from a prototype setup using 2 mm square fibers…
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented…
At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…
Muon tomography is a non-destructive imaging technique that exploits cosmic-ray muons from multiple directions. Its performance critically depends on the stability, active-area coverage, and spatial resolution of position-sensitive…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…
We report on the prototyping of a plastic scintillator hodoscope with wavelength-shifting fibre read-out by a multi-anode photomultiplier as part of the development of a detector for cosmic ray muons to be carried aboard an aircraft. Light…
Investigated in this work are sensitivities to non-standard neutrino interactions (NSI) of a prototype detector placed about 20 meters away from the Spallation Neutron Source at the Oak Ridge National Laboratory in two years of data taking.…
A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The…
In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high…