Related papers: NLC Luminosity as a Function of Beam Parameters
In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can…
The NLC extraction line provides a secondary focal point with a low beta function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV…
In order to aid in luminosity maximization at the interaction point (IP), the collision location $s_{IP}$ must be equivalent to the location of the minimum value of the beta function $s^*$. Accurate optics measurements and $s^*$ movements…
Properties of the disrupted NLC beam at the Interaction Point (IP) and particle loss in the extraction line are analyzed as a function of beam-to-beam position and angular offset at IP. The simulations show that disruption and beam loss…
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the…
The design luminosity for the future linear colliders is very demanding and challenging. Beam-based feedback systems will be required to achieve the necessary beam-beam stability and steer the two beams into collision. In particular we have…
The dense beams used at CLIC to achieve a high luminosity will cause a large amount of background particles through beam-beam interactions. Generator level studies with GuineaPig and full detector simulation studies with an ILD based CLIC…
Measurement of the integrated luminosity at the International Linear Collider (ILC) will be accomplished by counting the rate of small angle Bhabha scattering events. The physics requirements for ILC set the constraint on the relative…
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The…
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…
We present, for the first time, the local [CII] 158 um emission line luminosity function measured using a sample of more than 500 galaxies from the Revised Bright Galaxy Sample (RBGS). [CII] luminosities are measured from the Herschel PACS…
The goal of this study is to evaluate the impact of the latest ILC beam parameters at the Interaction Point (IP), as specified in the 2013 ILC Technical Design Report (TDR), on beam losses in the extraction line. The previous beam loss…
The first part of the physics programme of the integrated FCC (Future Circular Colliders) proposal includes measurements of Standard Model processes in $e^+e^-$ collisions (FCC-ee) with an unprecedented precision. In particular, the…
The internal linear combination (ILC) method is a popular approach for constructing component-separated maps in cosmic microwave background (CMB) analyses. It optimally combines observed maps at different frequencies to produce an unbiased…
We develop a framework for rendering photographic images, taking into account display limitations, so as to optimize perceptual similarity between the rendered image and the original scene. We formulate this as a constrained optimization…
In this note, we briefly review the current lattice of the NLC extraction line which was designed for the nominal NLC beam parameters. Then we describe the beam parameters for the high luminosity option with larger beam disruption parameter…
The performance of various systems of the Next Linear Collider (NLC) have been studied in terms of ground motion using recently developed models. In particular, the performance of the beam delivery system is discussed. Plans to evaluate the…
Analytical formulae for the calculation of secondary particle yields in p-A interactions are given. These formulae can be of great practical importance for fast calculations of neutrino fluxes and for designing new neutrino beam-lines. The…
A detailed description of an original method used to measure the luminosity accumulated by the HERA-B experiment for a data sample taken during the 2002-2003 HERA running period is reported. We show that, with this method, a total…
At the international linear collider, measurement of the beam profile at the interaction point is a key issue to achieve high luminosity. We report a simulation study on a new beam profile monitor, called the pair monitor, which uses the…