Related papers: HOTLink Rack Monitor
We have integrated a system of 16 RISC CPUs to help reconstruct and analyze a 1.3 Terabyte data set of 400 million high energy physics interactions. These new CPUs provided an affordable means of processing a very large data set. The data…
The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more…
A LLRF control and data acquisition system for the 8-cavity cryomodule1 at the ILCTA has been implemented using three 33-channel ADC boards in a VXI mainframe. One card each is dedicated to the cavity probes for vector control, forward…
The Fermilab Accelerator Division, Instrumentation Department is adopting an open-source framework to replace our embedded VME-based data acquisition systems. Utilizing an iterative methodology, we first moved to embedded Linux, removing…
Heat-assisted magnetic recording (HAMR) is a recent advancement in magnetic recording, allowing to significantly increase the areal density capability (ADC) of hard disk drives (HDDs) compared to the perpendicular magnetic recording (PMR)…
A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is based on 5 stations of silicon strip detectors having a…
An interlock system has been designed for the Fermilab Cryo-module Test Stand (CMTS), a test bed for the cryomodules to be used in the upcoming Linac Coherent Light Source 2 (LCLS-II) project at SLAC. The interlock system features 8…
Efficient operation of a submillimeter interferometer requires remote (preferably automated) control of mechanically tuned local oscillators, phase-lock loops, mixers, optics, calibration vanes and cryostats. The present control system for…
The Muon Campus (MC) is able to measure Muon g-2 with high precision and comparing its value to the theoretical prediction. The MC has four 300 KW screw compressors and four liquid helium refrigerators. The centerpiece of the Muon g-2…
Run II at the Fermilab Tevatron Collider started in March 2001, and it will continue probing the high energy frontier in particle physics until the start of the LHC at CERN. The CDF collaboration at Fermilab has already stored 260 TB of…
This paper presents an implementation of a smart power system using inter-device communication and supervisory control through Simulink integrated with the physical system. This control includes features of real-time control, load…
Remote control systems are becoming more and more important to give us the flexibility to control facilities, provide assistance and intervene in case of problems at any time and from every place. As a global operating group CALICE [2] with…
An extensible power supply control and monitoring system has been developed at Fermilab's Technical Division as a result of requirements to control and monior power supplies of various types from within many different applications. This…
To collect data for the study of charm particle decays, we built a high speed data acquisition system for use with the E791 magnetic spectrometer at Fermilab. The DA system read out 24000 channels in 50 uS. Events were accepted at the rate…
We introduce and demonstrate a hybrid optically pumped magnetometer (HOPM) that simultaneously measures one dc field component and one rf field component quadrature with a single atomic spin ensemble. The HOPM achieves…
The 9600 channels of the multi-wire proportional chamber of the H1 experiment at HERA have to be read out within 96 ns and made available to the trigger system. The tight spatial conditions at the rear end flange require a compact…
A longitudinal beam properties, data acquisition system has been commissioned to operate in the Fermilab booster ring. This system captures real time information including beam synchronous phase, bunch length, and coupled bunch instability…
In this paper, we present HOMULA-RIR, a dataset of room impulse responses (RIRs) acquired using both higher-order microphones (HOMs) and a uniform linear array (ULA), in order to model a remote attendance teleconferencing scenario.…
We present and evaluate the ExaNeSt Prototype, a liquid-cooled rack prototype consisting of 256 Xilinx ZU9EG MPSoCs, 4 TBytes of DRAM, 16 TBytes of SSD, and configurable interconnection 10-Gbps hardware. We developed this testbed in…
We describe a modular multi-channel data acquisition system based on the 5-15 Gigasample-per-second waveform-recording PSEC4 chip. The system architecture incorporates two levels of hardware with FPGA-embedded system control and in-line…