Related papers: Photoinjector design for the LCLS
The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e+e- linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures operating at high accelerating fields…
High current bright sources are needed to power the next generation of compact rf and microwave systems. A major requirement is that such a source could be sustainably operated at high frequencies, well above 1 GHz, and high gradients, well…
We developed an injection-locked Ti:sapphire laser at a wavelength of 671 nm where the fluorescence gain of the Ti:sapphire crystal is quite low. We obtained an output of more than 500 mW at a pump power of 10 W. The injection-locked lasing…
We present the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on a DC photoelectron gun and an SRF linac with multiple independently controlled accelerating and bunching cavities. The design is…
A 52MHz Radio Frequency Quadrupole (RFQ) linear accelerator (linac) is designed to serve as an initial structure for the SSC-linac system (injector into Separated Sector Cyclotron). The designed injection and output energy are 3.5 keV/u and…
In NSC KIPT linac, a neutron source based on a subcritical assembly driven by a 100MeV/100kW electron linear accelerator is under design and development. The linear accelerator needs a new high current electron gun. In this paper, the…
The second phase accelerator for the Dual Axis Hydrodynamic Test facility (DARHT) is designed to provide an electron beam pulse that is 2 microsec long, 2kA, and 20 MeV in particle energy. The injector provides 3.2 MeV so that the linac…
To make full use of photocathode material and improve its quantum efficiency lifetime, it can be necessary to operate laser away from the cathode center in photoinjectors. In RF guns, the off-axis emitted beam will see a time-dependent RF…
A solid-state laser system that produces a 1MHz pulse train of 800 pulses with 18 mJ per pulse at the wavelength of 263.5 nm has been developed to meet the requirements of the TESLA Test Facility (TTF) at Fermilab and in operation since…
Injected beam energy and energy spread are critical parameters affecting the performance of our rapid cycling synchrotron (RCS). A real-time energy monitoring system is being installed to examine the H- beam out of the Intense Pulsed…
Integrable optics is an innovation in particle accelerator design that potentially enables a greater betatron tune spread and damps collective instabilities. An integrable rapid-cycling synchrotron (RCS) would be an effective replacement…
The new 1.4 MeV/u front end HSI (HochStromInjektor) of the Unilac accelerates ions with A/q ratios of up to 65 and with beam intensities in emA of up to 0.25 A/q. The maximum beam pulse power is up to 1300 kW. During the stepwise linac…
The China spallation neutron source (CSNS) linac is designed with beam energy of 81MeV and a peak current of 15mA in the first phase. The RF power system for the 81 MeV Linac requires 8 units of RF power sources, each unit has one…
This paper describes the concept of a primary electron beam facility at CERN, to be used for dark gauge force and light dark matter searches. The electron beam is produced in three stages: A Linac accelerates electrons from a photo-cathode…
High-bunch-charge photoemission electron-sources operating in a continuous wave (CW) mode are required for many advanced applications of particle accelerators, such as electron coolers for hadron beams, electron-ion colliders, and…
To meet requirements of high performance THz-FEL (Free Electron Laser), a compact scheme of FEL injector was proposed. Thermionic cathode was chosen to emit electrons instead of photo-cathode with complex structure and high cost. The…
An S-band linear accelerator is the source of particles and the front end of the Advanced Photon Source injector. In addition, it supports a low-energy undulator test line (LEUTL) and drives a free-electron laser (FEL). A…
The spectrum of resonance fluorescence is calculated for a two-level system excited by an intense, ultrashort x-ray pulse made available for instance by free-electron lasers such as the Linac Coherent Light Source. We allow for inner-shell…
The PLS-II has a 100 MeV pre-injector for the 3 GeV Linac. A thermionic gun produces electron charge of 200 pC with a bunch duration of 500 ps by a 250 ps triggering pulser. At the pre-injector, one of the most important beam parameters to…
Increasing peak brightness is beneficial to various applications of Thomson scattering x-ray source. Higher peak brightness of scattered x-ray pulse demands shorter scattering electron beam realized by beam compression in electron…