Related papers: Processing Studies of X-Band Accelerator Structure…
During the initial phase of operation, the linacs of the Next Linear Collider (NLC) will contain roughly 5000 X-Band accelerator structures that will accelerate beams of electrons and positrons to 250 GeV. These structures will nominally…
X-band accelerator structures meeting the Next Linear Collider (NLC) design requirements have been found to suffer vacuum surface damage caused by radio frequency (RF) breakdown, when processed to high electric-field gradients. Improved…
Early tests of short low group velocity and standing wave structures indicated the viability of operating X-band linacs with accelerating gradients in excess of 100 MeV/m. Conventional scaling of traveling wave traveling wave linacs with…
In the NLC (Next Linear Collider) small misalignments in each of the individual accelerator structures (or the accelerator cells) will give rise to wakefields which kick the beam from its electrical axis. This wakefield can cause BBU (Beam…
Dielectric-loaded accelerating (DLA) structures are being studied as an alternative to conventional disk-loaded copper structures to produce the high accelerating gradient. This paper presents the design, fabrication and low-power RF…
In an effort to locate the cause(s) of high electric-field breakdown in x-band accelerating structures, we have cleanly-autopsied (no debris added by post-operation structure disassembly) an RF-processed structure. Macroscopic localization…
In order to mitigate the effects of electrical breakdown (which have been found to occur in SLAC X-band traveling wave structures) standing wave structures are being considered for the NLC linac. At SLAC, structures consisting of 15 cells…
In the framework of the upgrade of the SPARC_LAB facility at INFN-LNF, named EuPRAXIA@SPARC_LAB, a high gradient linac is foreseen. One of the most suitable options is to realize it in X-band. A preliminary design study of both accelerating…
Operating the SLAC/KEK DDS (Damped Detuned Structure) X-band linacs at high gradients (in excess of 70MV/m) has recently been found to be limited by the accelerator structures breaking down and as a consequence severe damage occurs to the…
Reducing the operating temperature of normal conducting particle accelerators substantially increases their efficiency. Low-temperature operation increases the yield strength of the accelerator material and reduces surface resistance, hence…
Use of a traveling wave (TW) accelerating structure with a small phase advance per cell instead of standing wave may provide a significant increase of accelerating gradient in a superconducting linear accelerator. The TW section achieves an…
The main linacs of the Next Linear Collider (NLC) will contain several thousand X-band RDDS (Rounded Damped Detuned Structures). The transverse wakefield in the structures is reduced by detuning the modal frequencies such that they…
The current profile along the 126 ns, multi-bunch beam pulse in the Next Linear Collider Test Accelerator (NLCTA) is monitored with fast toroids (rise time ~1 ns). Inserted at several positions along the beam line, they allow us to track…
The wire method is a more rapid and less costly method to measure impedances of RF components compared to methods using a beam. A setup using a single displaced wire to excite and measure transverse resonant modes in accelerating structures…
High-gradient linacs of next generation require novel accelerating structures which are compact, robust and cost-effective. Dedicated research and development have been launched in the linear-collider community. This paper focuses on the…
The low-level RF (LLRF) systems for linear accelerating structures are typically based on heterodyne architectures. The linear accelerators normally have many RF stations and multiple RF inputs and outputs for each station, so the…
High-gradient acceleration is a key research area that could enable compact linear accelerators for future colliders, light sources, and other applications. In the pursuit of high-gradient operation, RF breakdown limits the attainable…
The development of high gradient accelerating structures is one of the leading activities of the accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for…
Two standing-wave single-cell choke-mode damped structures with different choke dimensions which worked at 11.424 GHz were designed, manufactured and tuned by accelerator group in Tsinghua University. High power test was carried out to…
The transverse current profile in the Next Linear Collider Test Accelerator (NLCTA) electron beam can be monitored at several locations along the beam line by means of profile monitors. These consist of insertable phosphor screens, light…