Related papers: High-resolution TOF with RPCs
The analog front-end electronics based on the constant fraction discrimination method is designed and optimized for the Multigap Resistive Plate Chamber (MRPC) timing measurements. The total time resolution of 40 ps has been obtained for 10…
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data…
We describe a detector for measuring the time of flight of forward protons at the Large Hadron Collider (LHC) up to and beyond the full instantaneous design luminosity of 1034 cm-2 s-1. Our design is based on deep diffused, high gain…
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4\pi$. The high density of hits on a given particle track facilitates the task of pattern…
A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…
Resistive Plate Chambers (RPCs), used for the Muon Spectrometer of the ALICE experiment at CERN LHC, are currently operated in maxi-avalanche mode with a low threshold value and without amplification in the front-end electronics. RPC…
A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…
Low gain avalanche detectors can measure charged particle fluences with high speed and spatial precision, and are a promising technology for radiation monitoring and dosimetry. A detector has been tested in a medical linac where single…
We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…
A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam.…
Major advances in silicon pixel detectors, with outstanding timing performance, have recently attracted significant attention in the community. In this work we present and discuss the use of state-of-the-art Geiger-mode APDs, also known as…
In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming…
The ALICE Muon IDentifier is composed of 72 single-gap bakelite Resistive Plate Chambers, which have been operational since 2009 in maxi-avalanche mode (discrimination threshold:7 mV without amplification) with a…
The Multigap Resistive Plate Chambers (MRPC) are used as a timing detector in several particle physics and cosmic ray experiments. The gas mixture of MRPC at current experiments is a mixture containing $\rm C_2F_4H_2$ and in some cases $\rm…
Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders requires the use of time information in tracking, due to the increasing levels…
The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical…
Time Projection Chamber (TPC) is one of the main tracking systems for many current and future collider experiments at RHIC and LHC. It has a capability to measure the space points of charged tracks for good momentum resolution as well as…
This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber…
Precision timing has played a critical role in high-energy physics experiments, particularly for particle identification and the suppression of pileup under the challenging conditions expected at future colliders like the High-Luminosity…
Performances of several single gap (gas gap 2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive ({\rho} \sim 1010 - 1012 {\Omega} cm) bakelite, commercially available in India have been studied in recent times. To make the…