Related papers: Observation of a H- Beam Ion Instability
The ion-hose (or fast-ion) instability sets limits on the allowable vacuum in a long-pulse, high current accelerator. Beam-induced ionization of the background gas leads to the formation of an ion channel which couples to the transverse…
The Fermilab Linac delivers 400MeV, 25mA H$^-$; beam. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the…
The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed…
The Drive Beam Linac of the Compact Linear Collider (CLIC) has to accelerate an electron beam with 4.2 A up to 2.4 GeV in almost fully-loaded structures. The pulse contains about 70000 bunches, one in every second rf bucket, and has a…
The Proton Improvement Plan, Stage Two (PIP-II) is a program of upgrades proposed for the Fermilab injection complex, which central part is an 800 MeV, 2 mA CW SRF linac. A prototype of the PIP-II linac front end called PIP-II Injector Test…
The intensity of charged particle beams at Fermilab must be kept within pre-determined safety and operational envelopes in part by assuring all beam within a few percent has been transported from any source to destination. Beam intensity…
The new 1.4 MeV/u front end HSI (HochStromInjektor) of the Unilac accelerates ions with A/q ratios of up to 65 and with beam intensities in emA of up to 0.25 A/q. The maximum beam pulse power is up to 1300 kW. During the stepwise linac…
For modern high-intensity linear accelerators, the well-known envelope instability and recently reported fourth-order particle resonance impose a fundamental operational limit (i.e., zero-current phase advance should be less than 90 deg).…
We analyze experimentally the behavior of a non-Brownian, iso-dense suspension of spheres submitted to periodic square wave oscillations of the flow in a Hele-Shaw cell of gap $H$. We do observe an instability of the initially homogeneous…
The robustness of a structured collimation device is discussed for an intense-laser-produced ion beam. In this paper the ion beam collimation is realized by the solid structured collimation device, which produces the transverse electric…
The general question of how a beam becomes unstable has been one of the fundamental research topics among beam and accelerator physicists for several decades. In this study, we revisited the general problem of linear beam stability in…
The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of…
A superintense laser pulse illuminating a thin solid-density foil can, in principle, accelerate the entire foil, therefore yielding dense, collimated, and quasi-monoenergetic ion beams. These unique features render radiation pressure…
An ion beam can destabilize Alfv\'en/ion-cyclotron waves and magnetosonic/whistler waves if the beam speed is sufficiently large. Numerical solutions of the hot-plasma dispersion relation have previously shown that the minimum beam speed…
The optical conductivity of the new Dirac semimetal candidate Ir$_2$In$_8$Se is measured in a frequency range from 40 to 30000 cm$^{-1}$ at temperatures from 300 K down to 10 K. The measurement reveals that the compound is a low carrier…
We report results of the beam commissioning and first operation of the 1.3 GHz superconducting RF electron linear accelerator at Fermilab Accelerator Science and Technology (FAST) facility. Construction of the linac was completed and the…
A multi-stream instability is observed experimentally in a longitudinally expanding electron beam in a storage ring. The instability is observed when the beam expands such that its length is several times the circumference of the ring, and…
In this paper, we report our multiwavelength observations of the large-amplitude longitudinal oscillations of a filament on 2015 May 3. Located next to active region 12335, the sigmoidal filament was observed by the ground-based H$\alpha$…
The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic…
The first phase of the HIE-ISOLDE project at CERN consists of a superconducting (SC) linac upgrade in order to increase the energy of post-accelerated radioactive ion beams from 2.8 MeV/u to over 10 MeV/u (for A/q = 4.5). In preparation for…