Related papers: Beam Loading Compensation in the Main Linac of CLI…
Future linear colliders plan to collide polarised beams and the planned physics reach requires knowledge of the state of polarisation as precisely as possible. The polarised beams can undergo depolarisation due to various mechanisms. In…
To achieve the physics goals of future Linear Colliders, it is important that electron and positron beams are polarized. The positron source planned for the International Linear Collider (ILC) is based on a helical undulator system and can…
A linac (linear accelerator) is a system that allows to accelerate charged particles through a linear trajectory by electromagnetic fields. This kind of accelerator finds several applications in fundamental research and industry. The main…
We present a new conceptual and optical design for the Next Linear Collider post-linac collimation system. Energy collimation and passive protection against off-energy beams are achieved in a system with large horizontal dispersion and…
The compact linear collider (CLIC) requires a crab cavity to align bunches prior to collision. The bunch structure demands tight amplitude and phase tolerances of the RF fields inside the cavity, for the minimal luminosity loss. Beam…
The baseline configuration of the International Linear Collider requires 2 beam dumps per interaction region, each rated to 18MW of beam power, together with additional beam dumps for tuning purposes and machine protection. The baseline…
In polarized proton operation, the performance of the Relativistic Heavy Ion Collider (RHIC) is limited by the head-on beam-beam effect. To overcome this limitation, two electron lenses are under commissioning. We give an overview of…
CLIC is a proposed linear $e^+e^-$ collider with center-of-mass energies of up to 3 TeV. Its main objectives are precise top quark, Higgs boson and Beyond Standard Model physics. In addition to spatial resolutions of a few micrometers and a…
The Compact Linear Collider (CLIC) is a concept for a future linear collider that would provide e$^+$e$^-$ collisions at up to 3 TeV. The physics aims require a detector system with excellent jet energy and track momentum resolution, highly…
The injector linacs of the JLC/NLC comprise the e+ booster, the e- drive linac, the e+ booster, and the two prelinacs. These four systems together transport the two types of beams from the 80 MeV point at the end of their respective…
There is demand for the construction of a medium-energy ion linear accelerator based on superconducting rf (SRF) technology. It must be capable of producing several hundred kilowatts of CW beams ranging from protons to uranium. A…
The Fermi National Accelerator Laboratory (Fermilab) Linac accepts 750 keV H- ions from the front end and accelerates them to 400 MeV for injection into the Booster rapid cycling synchrotron. Day-to-day drifts in the beam longitudinal…
The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision.…
For the CLIC two-beam scheme, a high-current, long-pulse drive beam is required for RF power generation. Taking advantage of the 3 GHz klystrons available at the LEP injector once LEP stops, a 180 MeV electron accelerator is being…
The Fermilab Linac accepts the 0.75 MeV H- ions from the front end and accelerates them to 400 MeV for injection into the Booster. Day-to-day drifts of the longitudinal trajectory in the Linac, reconstructed from phase readings of Beam…
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving…
The upcoming Proton Improvement Plan-II (PIP-II), designated for enhancements to the Fermilab accelerator complex, features a new 800 MeV superconducting linac and a Beam Transfer Line (BTL) to transport the beam to the existing Booster…
The dense beams used at CLIC to achieve a high luminosity will cause a large amount of background particles through beam-beam interactions. Generator level studies with GuineaPig and full detector simulation studies with an ILD based CLIC…
The Compact Linear Collider (CLIC) is a proposed high-luminosity collider that would collide electrons with their antiparticles, positrons, at energies ranging from a few hundred Giga-electronvolts (GeV) to a few Tera-electronvolts (TeV).…
Collimation systems in particle accelerators are designed to dispose of unavoidable losses safely and efficiently during beam operation. Different roles are required for different types of accelerator. The present state of the art in beam…