English
Related papers

Related papers: Beam Position-Phase Monitors for SNS Linac

200 papers

The paper proposes a method of finding the beam loss locations in a linac. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync produces a line at the…

Accelerator Physics · Physics 2019-05-02 Alexander Shemyakin

In superconducting linear accelerators (linacs), accurately monitoring beam dynamics is essential for minimizing beam losses and ensuring stable operations. However, destructive diagnostics must be avoided in superconducting sections to…

The Front End of the Spallation Neutron Source (SNS) extends from the Ion Source (IS), through a 65 keV LEBT, a 402.5 MHz RFQ, a 2.5 MeV MEBT, ending at the entrance to the DTL. The diagnostics suite in this space includes stripline beam…

Accelerator Physics · Physics 2010-11-15 L. Doolittle , T. Goulding , D. Oshatz , A. Ratti , J. Staples

A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four…

Instrumentation and Detectors · Physics 2019-09-25 Xingshun Gao , Lei Zhao , Jinxin Liu , Zouyi Jiang , Xiaofang Hu , Shubin Liu , Qi An

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed…

Accelerator Physics · Physics 2025-09-18 A. Shemyakin , J. Kuharik , R. Sharankova

The Fermilab Linac delivers a variable intensity, 400-MeV beam to the The MuCool Test Area experimental hall via a beam line specifically designed to facilitate measurements of the Linac beam emittance and properties. A 10 m,…

Accelerator Physics · Physics 2013-01-30 F. G. G. Garcia , C. Johnstone , T. Kobilarcik , G. M. Koizumi , C. D. Moore , D. L. Newhart

The China spallation neutron source (CSNS) linac is designed with beam energy of 81MeV and a peak current of 15mA in the first phase. The RF power system for the 81 MeV Linac requires 8 units of RF power sources, each unit has one…

Accelerator Physics · Physics 2019-09-26 Linyan Rong , Zhencheng Mu , Zhexin Xie , Bo Wang , Wenzhong Zhou , Maliang Wan , Meifei Liu , Jian Li , Xinan Xu

The SNS linac accelerates an average beam current of 2 mA to an energy of 968 MeV. The linac is pulsed at 60 Hz with an H- beam pulse of 1 ms. The first 185 Mev of the linac uses normal conducting cavities, and the remaining length of the…

Accelerator Physics · Physics 2007-05-23 Michael Lynch , William Reass , Daniel Rees , Amy Regan , Paul Tallerico

Injected beam energy and energy spread are critical parameters affecting the performance of our rapid cycling synchrotron (RCS). A real-time energy monitoring system is being installed to examine the H- beam out of the Intense Pulsed…

Accelerator Physics · Physics 2009-09-25 J. C. Dooling , F. R. Brumwell , M. K. Lien , G. E. McMichael

The Fermilab Linac delivers 400MeV, 25mA H$^-$; beam. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the…

Accelerator Physics · Physics 2025-09-18 R. Sharankova , J-P. Carneiro , E. Chen , A. Shemyakin

This paper describes beam energy online measurement of BEPCII linac, presents the calculation formula and some of the results. The method mentioned here measures the beam energy by acquiring beam positions in the horizontal direction with…

Accelerator Physics · Physics 2015-10-09 Shao-Zhe Wang , Rong Liu , Yun-Long Chi

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 117 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole…

Accelerator Physics · Physics 2025-09-18 J. -P. Carneiro , E. Chen , A. Pathak , R. Sharankova , A. Shemyakin

The Spallation Neutron Source (SNS) is being designed, constructed, installed and commissioned by the staff of six national laboratories, Argonne National Laboratory, Brookhaven National Laboratory, Jefferson National Accelerator…

Accelerator Physics · Physics 2007-05-23 Robert L. Kustom

Suppression of beam losses is essential for successful operation of high-intensity linac. Historically, the values of the field amplitudes and phases of the side-coupled, 805-MHz LANSCE linac modules are maintained using a well-known…

Accelerator Physics · Physics 2020-02-26 Y. K. Batygin , F. E. Shelley , H. A. Watkins

For the characterization of the 10 mA ion beam delivered by the new High Current Linac at GSI, sophisticated, mainly non-intersepting diagnostic devices were developed. Besides the general set-up of a versatile test bench, we discuss in…

Accelerator Physics · Physics 2007-05-23 P. Forck , F. Heymach , T. Hoffmann , A. Peters , P. Strehl

In the National Spallation Neutron Source (NSNS) design, a 180 meter long transport line connects the 1 GeV linac to an accumulator ring. The linac beam has a current of 28 mA, pulse length of 1 ms, and 60 Hz rep rate. The high energy…

Accelerator Physics · Physics 2008-11-26 D. Raparia , J. Alessi , Y. Y. Lee , W. T. Weng

The beam position monitor (BPM) system for Fermilab Switchyard (SY) provides the position, intensity and integrated intensity of the 53.10348 MHz RF bunched resonant extracted beam from the Main Injector over 4 seconds of spill. The total…

Accelerator Physics · Physics 2015-02-09 P. Stabile , J. S. Diamond , J. A. Fitzgerald , N. Liu , D. K. Morris , P. S. Prieto , J. P. Seraphin

The conception of High Power Linac developed in Russian accelerator centres is based on the use of independently phased SC resonators with quadrupole lenses between them. The type and parameters of the resonators as well as focusing…

Accelerator Physics · Physics 2007-05-23 A. Kolomiets , S. Yaramishev

Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…

The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster…

Accelerator Physics · Physics 2024-09-05 E. Chen , R. Sharankova , A. Shemyakin , J. Stanton
‹ Prev 1 2 3 10 Next ›