English
Related papers

Related papers: Linac Lue200. First Testing Results

200 papers

Preinjector VEPP-5 electron linac consists of two linear accelerators on energy 300 MeV and 510 MeV and includes 14 accelerating structures [1]. First accelerating structures both linacs have increased average rate of acceleration 25-30…

Accelerator Physics · Physics 2007-05-23 5 Team

The Pohang Accelerator Laboratory operates an electron linac for the pulsed neutron source as one of the long-term nuclear R&D programs at the Korea Atomic Energy Research Institute. The designed beam parameters are as follows; The nominal…

Accelerator Physics · Physics 2008-11-26 G. N. Kim , H. S. Kang , Y. S. Lee , M. H. Cho , I. S. Ko , W. Namkung

The construction of the initial part of a normally conducting linac for hydrogen ion beams with a pulsed current of ~20 mA up to an energy of ~70 MeV is considered. The RFQ at a frequency of ~160 MHz accelerates ions to an energy of ~4 MeV.…

Accelerator Physics · Physics 2023-09-21 V. V. Paramonov , A. P. Durkin , L. Yu. Ovchinnikova , I. V. Rybakov

The Proton Improvement Plan-II (PIP-II) [1] has been developed at Fermilab to provide powerful proton beams to the laboratorys experiments. An 800-MeV superconducting linear accelerator-a centerpiece of the project-is currently under…

Accelerator Physics · Physics 2023-01-23 Igor Rakhno , Nikolai Mokhov , Igor Tropin , Sergei Striganov , Yury Eidelman

LINAC 4 is a normal conducting H- structure proposed to intensify the proton flux currently available for the CERN accelerator chain. This linac is designed to accelerate a 65 mA beam up to 160 MeV to be injected into the CERN Proton…

Accelerator Physics · Physics 2014-11-18 M. Baylac , J. M. De Conto , E. Froidefond , E. Sargsyan

IHEP, China is constructing a 100 MeV / 100 kW electron Linac for NSC KIPT, Ukraine. This linac will be used as the driver of a neutron source based on a subcritical assembly. In 2012, the injector part of the accelerator was pre-installed…

The demand for neutron production facilities is increasing, as the applications of neutron science are manifold. These applications drive the need for efficient and compact neutron sources. In this context, this paper explores the potential…

The construction of the 60-MeV proton linac has started as a low-energy front of the KEK/JAERI Joint Project for a high-intensity proton accelerator facility at KEK. The accelerating frequency is 324 MHz. Five UHF klystrons are used as an…

Accelerator Physics · Physics 2007-05-23 S. Fukuda , A. Anami , C. Kubota , M. Kawamura , S. Yamaguchi , M. Ono , H. Nakanishi , S. Miyake , M. Sakamoto

In NSC KIPT linac, a neutron source based on a subcritical assembly driven by a 100MeV/100kW electron linear accelerator is under design and development. The linear accelerator needs a new high current electron gun. In this paper, the…

Accelerator Physics · Physics 2015-06-17 Zusheng Zhou , Dayong He , Yunlong Chi

The accelerator for the APT Project is a 100 mA CW proton linac with an output energy of 1030 MeV. A High Energy Beam Transport (HEBT) conveys the beam to a raster expander, that provides a large rectangular distribution at a target/blanket…

Accelerator Physics · Physics 2008-11-26 J. F. Tooker , R. Bourque , D. Christiansen , J. Kamperschroer , G. Laughon , M. McCarthy , M. Schulze

The peak current limit for the Fermilab Linac was recently studied. The purpose was to learn what components of the present Linac can be used for the first stage of a proposed proton driver[1]. For this application the Linac must provide a…

Accelerator Physics · Physics 2007-05-23 M. Popovic , L. Allen , A. Moretti , E. McCrory , C. W. Schmidt , T. Sullivan

The creation of intense radioactive beams requires intense and energetic primary beams. A task force analysis of this subject recommended an acceleration system capable of 400 MeV/u uranium at 1 particle uA as an appropriate driver for such…

Nuclear Experiment · Physics 2007-05-23 F. Marti , R. C. York , H. Blosser , M. M. Gordon , D. Gorelov , T. Grimm , D. Johnson , P. Miller , E. Pozdeyev , J. Vincent , X. Wu , A. Zeller

Following the PIP-II 800 MeV Linac, Fermilab will need an accelerator that extends from that linac to the MI injection energy of ~8 GeV, completing the modernization of the Fermilab high-intensity accelerator complex. This will maximize the…

The H- Accelerator consists of a 750 keV Cockcroft Walton preaccelerator and an Alvarez type 50 MeV linac. The accelerator has been in operation since 1961. Since 1981, it has been used as the injector for the Intense Pulsed Neutron Source…

Accelerator Physics · Physics 2007-05-23 L. I. Donley , V. F. Stipp , F. R. Brumwell , G. E. McMichael

PIP-II is the Fermilab's flagship project for providing powerful, high-intensity proton beams to the laboratory's experiments. The heart of PIP-II is an 800-MeV superconducting linac accelerator. It will be located in a new tunnel with new…

Accelerator Physics · Physics 2018-06-18 L. Lari , F. Cerutti , L. S. Esposito , C. Baffes , S. J. Dixon , N. V. Mokhov , I. Rakhno , I. S. Tropin

ANL and the National Science Center "Kharkov Institute of Physics Technology" (NSC KIPT, Kharkov, Ukraine) jointly proposed to design and build a 100MeV/100KW linear accelerator which will be used to drive the neutron source subcritical…

Accelerator Physics · Physics 2015-06-11 Mi Hou , Xiang He , Shilun Pei

We report results of the beam commissioning and first operation of the 1.3 GHz superconducting RF electron linear accelerator at Fermilab Accelerator Science and Technology (FAST) facility. Construction of the linac was completed and the…

A 52MHz Radio Frequency Quadrupole (RFQ) linear accelerator (linac) is designed to serve as an initial structure for the SSC-linac system (injector into Separated Sector Cyclotron). The designed injection and output energy are 3.5 keV/u and…

Accelerator Physics · Physics 2016-09-08 Xiao Chen , He Yuan , Yuan You-Jin , Liu Yong , Xia Jia-Wen , Lu Yuan-Rong , Yuri Batygin

The China spallation neutron source (CSNS) linac is designed with beam energy of 81MeV and a peak current of 15mA in the first phase. The RF power system for the 81 MeV Linac requires 8 units of RF power sources, each unit has one…

Accelerator Physics · Physics 2019-09-26 Linyan Rong , Zhencheng Mu , Zhexin Xie , Bo Wang , Wenzhong Zhou , Maliang Wan , Meifei Liu , Jian Li , Xinan Xu

As the pre-injector of the LHC injector chain, the proton linac at CERN is required to provide a high-intensity (180mA) beam to the Proton Synchrotron Booster. The results of measurements at this intensity will be presented. Furthermore,…

Accelerator Physics · Physics 2007-05-23 C. E. Hill , A. Lombardi , R. Scrivens , M. Vretenar , A. Feschenko , A. Liou
‹ Prev 1 2 3 10 Next ›