Related papers: High-intensity single-bunch electron beam generati…
This document describes the concept of a primary electron beam facility at CERN, to be used for dark gauge force and light dark matter searches. The electron beam is produced in three stages: A Linac accelerates electrons from a…
In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an…
The Electron-Ion Collider is under construction at BNL. It will have high-energy high-intensity polarized beams of electrons and hadrons. These beams will allow a high accuracy investigation of nucleon structure in the low- to very-low-x…
This paper describes the concept of a primary electron beam facility at CERN, to be used for dark gauge force and light dark matter searches. The electron beam is produced in three stages: A Linac accelerates electrons from a photo-cathode…
The KAHVE Laboratory, at Bo\u{g}azi\c{c}i University, Istanbul, Turkey is home to an educational proton linac project. The proton beam will originate from a 20 keV H+ source and will be delivered to a two module Radio Frequency Quadrupole…
The Linac to End Station A (LESA) beamline is being constructed at SLAC and will provide a near-CW beam of multi-GeV electrons to the SLAC End Station A for experiments in particle physics. The 1st half of LESA is ready for commissioning at…
A laser-Compton backscattering beam, which we call a `Laser-Electron Photon' beam, was upgraded at the LEPS beamline of SPring-8. We accomplished the gains in backscattered photon beam intensities by factors of 1.5--1.8 with the injection…
The new 1.4 MeV/u front end HSI (HochStromInjektor) of the Unilac accelerates ions with A/q ratios of up to 65 and with beam intensities in emA of up to 0.25 A/q. The maximum beam pulse power is up to 1300 kW. During the stepwise linac…
The Linac Coherent Light Source (LCLS) project at SLAC uses a dense 15 GeV electron beam passing through a long undulator to generate extremely bright x-rays at 1.5 angstroms. The project requires electron bunches with a nominal peak…
A novel room-temperature ion source for the production of atomic ions in electron beam within wide ranges of electron energy and current density is developed. The device can operate both as conventional Electron Beam Ion Source/Trap…
The conception of High Power Linac developed in Russian accelerator centres is based on the use of independently phased SC resonators with quadrupole lenses between them. The type and parameters of the resonators as well as focusing…
As a part of future developments of beam diagnostics, a low energy experimental bench (LEEx-B) has been recently designed, built and commissioned at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on a HV platform…
The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster…
This report describes a concept of an EIC cooling system, based on a proven induction linac technology with a dc electron beam. The system would operate in a full energy range of proton beams (100 - 270 GeV) and would provide 50-100 A…
Using a high energy electron beam for the imaging of high density matter with both high spatial-temporal and areal density resolution under extreme states of temperature and pressure is one of the critical challenges in high energy density…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…
The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e+e- linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures operating at high accelerating fields…
We report on a successful test of a new method for intense ion beam formation using an extraction with inhomogeneous electric field. Its key feature is a special shape of the extraction electrodes providing a higher rate of ion…
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving…
Recently, there is an increasing need for $H_{2}^+$ and $H_{3}^+$ ion sources. One example are ion therapy facilities, where $C^{4+}$ and $H_{3}^+$ ion beams along the linac are of great interest. Another example is a $H_{2}^+$ test beam…