Related papers: A high-precision polarimeter
A major advance in accurate electron beam polarization measurement has been achieved at Jlab Hall A with a Compton polarimeter based on a Fabry-Perot cavity photon beam amplifier. At an electron energy of 4.6 GeV and a beam current of 40…
As part of the spin physics program at Jefferson Laboratory (JLab), a M\o ller polarimeter was developed to measure the polarization of electron beam of energies 0.8 to 5.0 GeV. A unique signature for M\o ller scattering is obtained using a…
We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A total uncertainty of dP/P=0.36% was…
The M{\o}ller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades reaching the typically required $\pm$1\% level of absolute uncertainty.…
The International Linear Collider (ILC) will collide polarised electrons and positrons at beam energies of 45.6 GeV to 250 GeV and optionally up to 500 GeV. To fully exploit the physics potential of this machine, not only the luminosity and…
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson…
For the 1994/95 run of the SLD experiment at SLAC, a Compton polarimeter measured the luminosity-weighted electron beam polarization to be (77.2 +- 0.5)%. This excellent accuracy is achieved by measuring the rate asymmetry of…
We have performed a novel comparison between electron-beam polarimeters based on M{\o}ller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $\mu$A) during the $Q_{\rm…
We report on the design and construction of a high-energy photon polarimeter for measuring the degree of polarization of a linearly-polarized photon beam. The photon polarimeter uses the process of pair production on an atomic electron…
A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a…
The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…
The physics program at the upgraded Jefferson Lab (JLab) and the physics program envisioned for the proposed electron-ion collider (EIC) include large efforts to search for interactions beyond the Standard Model (SM) using parity violation…
A novel precision polarimeter will go a long way in satisfying the requirements of the precision experiments being planned for a future facility such as the Electron Ion Collider. A polarimeter based on the asymmetry in the spacial…
A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing…
We present commissioning data for the POLISH instrument obtained on the Hale 5-m telescope. The goal of this high precision polarimeter is to constrain orbital inclination of high mass X-ray binaries and to therefore obtain independent mass…
We have built and tested a compact, low-cost, but very-high-performance astronomical polarimeter based on a continuously rotating half-wave plate and a high-speed imaging detector. The polarimeter is suitable for small telescopes up to ~1 m…
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of…
An electron beam polarization of 80% or greater will be a key feature of a 1 TeV Linear Collider. Accurate measurements of the beam polarization will therefore be needed. We discuss design considerations and capabilities for a…
The Relativistic Heavy Ion Collider at Brookhaven National Laboratory provides polarized proton beams for the investigation of the nucleon spin structure. For polarimetry, carbon-proton and proton-proton scattering is used in the Coulomb…
POLAR is a compact polarimeter dedicated to measure the polarization of GRBs between 50-300 keV. The light collection of 200*6*6mm3 plastic bars has been simulated and optimized in order to get uniform response to x-rays at different points…