Related papers: MSX - A Monte-Carlo Code for Neutron Efficiency Ca…

200 papers

We present the design of an instrument capable of measuring the high energy ($>$60 MeV) muon-induced neutron flux deep underground. The instrument is based on applying the Gd-loaded liquid-scintillator technique to measure the rate of…

Astrophysics · Physics 2008-11-26 R. Hennings-Yeomans , D. S. Akerib

In order to develop a high spatial resolution (micron level) thermal neutron detector, a detector assembly composed of cerium doped lithium glass microfibers, each with a diameter of 1\,$\mu$m, is proposed, where the neutron absorption…

Instrumentation and Detectors · Physics 2016-06-14 Song Yushou , Joseph Conner , Xiaodong Zhang , Jason P. Hayward

There has been an increasing interest in the monitoring of nuclear fuel for power reactors by detecting the anti-neutrinos produced during operation. Small liquid scintillator detectors have already demonstrated sensitivity to operational…

Instrumentation and Detectors · Physics 2007-05-23 R. W. McKeown , D. E. Reyna

We describe the Monte Carlo (MC) simulation package of the Borexino detector and discuss the agreement of its output with data. The Borexino MC 'ab initio' simulates the energy loss of particles in all detector components and generates the…

The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind…

Neutron time correlation measurements are used to characterize fissile systems. For this purpose, detailed information are obtained using list mode measurements where the neutron detection times are recorded in a file called the time list…

Instrumentation and Detectors · Physics 2024-12-18 Philippe Humbert

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can…

Instrumentation and Detectors · Physics 2023-03-01 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…

Instrumentation and Detectors · Physics 2015-06-15 C. Zhang , D. -M. Mei , P. Davis , B. Woltman , F. Gray

Expected energy spectra calculations for large volume liquid scintillation detectors to inverse $\beta$-decay for antineutrinos produced by $^{144}$Ce -- $^{144}$Pr artificial source have been performed. The calculations were carried out…

High Energy Physics - Phenomenology · Physics 2019-05-17 A. V. Derbin , I. S. Drachnev , I. S. Lomskaya , V. N. Muratova , N. V. Pilipenko , D. A. Semenov , E. V. Unzhakov

A detailed Monte-Carlo code has been developed from basic principles that simulates almost all of the basic photon and charged particle interactions. The code is used to derive the response functions of a high energy photon detector to…

Instrumentation and Detectors · Physics 2008-10-03 Srikanta Sinha

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

In this paper we present Monte Carlo N-Particle (MCNP) simulations of the system for underwater threat detection using neutron activation analysis developed in the SABAT project. The simulated system is based on a D-T neutron generator…

Instrumentation and Detectors · Physics 2019-10-08 P. Sibczyński , M. Silarski , O. Bezshyyko , V. Ivanyan , E. Kubicz , Sz. Niedźwiecki , P. Moskal , J. Raj , S. Sharma , O. Trofimiuk

Ultracold neutrons (UCN) with kinetic energies up to 300 neV can be stored in material or magnetic confinements for hundreds of seconds. This makes them a very useful tool for probing fundamental symmetries of nature, by searching for…

Instrumentation and Detectors · Physics 2018-12-26 N. J. Ayres , E. Chanel , B. Clement , P. G. Harris , R. Picker , G. Pignol , W. Schreyer , G. Zsigmond

The organic liquid scintillator used in the LVD experiment (INFN Gran Sasso National Laboratory) has been exposed to an Am-Be neutron source to measure the light response function for neutron energies in the region from about 4 to 11 MeV. A…

Instrumentation and Detectors · Physics 2014-10-22 G. Bruno

Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in high-energy physics…

Instrumentation and Detectors · Physics 2019-01-01 D. M. Poehlmann , D. Barker , H. Chagani , P. Cushman , G. Heuermann , A. Medved , H. E. Rogers , R. Schmitz

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 -- 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino…

A full simulation of a transition radiation detector (TRD) based on the GEANT, GARFIELD, MAGBOLTZ and HEED codes has been developed. This simulation can be used to study and develop TRD for high energy particle identification using either…

Computational Physics · Physics 2016-09-08 M. N. Mazziotta

This document describes a Monte-Carlo simulation of an underwater neutrino telescope with a homogeneous detection volume of a cubic kilometre.

High Energy Physics - Experiment · Physics 2019-08-14 D. Zaborov

A Monte Carlo code has been developed to simulate the operation of the planned detectors in OMNIS, a supernova neutrino observatory. OMNIS will detect neutrinos originating from a core collapse supernova by the detection of spalled neutrons…

Nuclear Experiment · Physics 2009-11-07 J. J. Zach , A. StJ. Murphy , D. Marriott , R. N. Boyd

The JUNO neutrino detector system is simulated using Monte-Carlo and analytical methods. A large number of proton decay events are also simulated. Preliminary results from this endeavor are presented in the present article.

Instrumentation and Methods for Astrophysics · Physics 2020-01-29 Srikanta Sinha
‹ Prev 1 2 3 10 Next ›