English
Related papers

Related papers: Operation of a high purity germanium crystal in li…

200 papers

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta…

Instrumentation and Detectors · Physics 2023-08-24 GERDA collaboration , M. Agostini , A. Alexander , G. R. Araujo , A. M. Bakalyarov , M. Balata , I. Barabanov , L. Baudis , C. Bauer , S. Belogurov , A. Bettini , L. Bezrukov , V. Biancacci , E. Bossio , V. Bothe , R. Brugnera , A. Caldwell , S. Calgaro , C. Cattadori , A. Chernogorov , P-J. Chiu , T. Comellato , V. D'Andrea , E. V. Demidova , A. Di Giacinto , N. Di Marco , E. Doroshkevich , F. Fischer , M. Fomina , A. Gangapshev , A. Garfagnini , C. Gooch , P. Grabmayr , V. Gurentsov , K. Gusev , J. Hakenmüller , S. Hemmer , W. Hofmann , M. Hult , L. V. Inzhechik , J. Janicskó Csáthy , J. Jochum , M. Junker , V. Kazalov , Y. Kermaïdic , H. Khushbakht , T. Kihm , K. Kilgus , I. V. Kirpichnikov , A. Klimenko , K. T. Knöpfle , O. Kochetov , V. N. Kornoukhov , P. Krause , V. V. Kuzminov , M. Laubenstein , B. Lehnert , M. Lindner , I. Lippi , A. Lubashevskiy , B. Lubsandorzhiev , G. Lutter , C. Macolino , B. Majorovits , W. Maneschg , L. Manzanillas , G. Marshall , G. Marshall , M. Miloradovic , R. Mingazheva , M. Misiaszek , M. Morella , Y. Müller , I. Nemchenok , M. Neuberger , L. Pandola , K. Pelczar , L. Pertoldi , P. Piseri , A. Pullia , L. Rauscher , M. Redchuk , S. Riboldi , N. Rumyantseva , C. Sada , S. Sailer , F. Salamida , S. Schönert , J. Schreiner , M. Schütt , A-K. Schütz , O. Schulz , M. Schwarz , B. Schwingenheuer , O. Selivanenko , E. Shevchik , M. Shirchenko , L. Shtembari , H. Simgen , A. Smolnikov , D. Stukov , S. Sullivan , A. A. Vasenko , A. Veresnikova , C. Vignoli , K. von Sturm , A. Wegmann , T. Wester , C. Wiesinger , M. Wojcik , E. Yanovich , B. Zatschler , I. Zhitnikov , S. V. Zhukov , D. Zinatulina , A. Zschocke , A. J. Zsigmond , K. Zuber , G. Zuzel

A proof of concept detector is presented for scintillation light detection in liquid argon using Silicon Photo-Multipliers. The aim of the work is to build an anti-Compton veto for germanium detectors operated directly in liquid argon like…

Instrumentation and Detectors · Physics 2016-06-15 József Janicskó Csáthy , Hossein Aghaei Khozani , Xiang Liu , Béla Majorovits , Allen Caldwell

Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\pi$…

Instrumentation and Detectors · Physics 2008-11-26 M. Di Marco , P. Peiffer , S. Schönert

The use of High Purity Germanium detectors operated in ionization mode at cryogenic temperatures is investigated as an external background mitigation solution for bolometers used in rare-event search experiments. A simple experimental setup…

High Energy Physics - Experiment · Physics 2025-09-05 Chloé Goupy , Stefanos Marnieros , Beatrice Mauri , Claudia Nones , Matthieu Vivier

The GERmanium Detector Array, GERDA, will search for neutrinoless double beta decay in 76Ge at the National Gran Sasso Laboratory of the INFN. Bare high-purity germanium detectors enriched in 76Ge will be submerged in liquid argon serving…

The shape of the undepleted volume of a p-type high-purity Broad Energy Germanium detector, dependent on the bias voltage, has been imaged by measuring spatially-resolved Compton-scattering efficiency. The bias voltage was raised stepwise…

Instrumentation and Detectors · Physics 2026-02-18 Iris Abt , Arthur Butorev , Felix Hagemann , David Hervas Aguilar , Johanna Lührs , Julia Penner , Oliver Schulz

In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high…

Instrumentation and Detectors · Physics 2016-06-15 J. Janicskó Csáthy , T. Bode , J. Kratz , S. Schönert , Ch. Wiesinger

For the first time, planar high-purity germanium detectors with thin amorphous germanium contacts were successfully operated directly in liquid nitrogen and liquid argon in a cryostat at the Max-Planck-Institut fuer Physics in Munich. The…

Instrumentation and Detectors · Physics 2020-08-04 R. Panth , J. Liu , I. Abt , X. Liu , O. Schulz , W. -Z. Wei , H. Mei , D. -M. Mei , G. -J. Wang

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost…

In searching for the neutrinoless double-beta decay of $^{76}$Ge the GERmanium Detector Array (GERDA) experiment at the INFN Laboratori Nazionali del Gran Sasso has achieved an unprecedented low background of well below 10$^{-3}$…

Instrumentation and Detectors · Physics 2022-03-02 K. T. Knöpfle , B. Schwingenheuer

LArGe is a GERDA low-background test facility to study novel background suppression methods in a low-background environment, for future application in the GERDA experiment. Similar to GERDA, LArGe operates bare germanium detectors submersed…

Diverse searches for direct dark matter (DM) in effective electromagnetic and leptophilic interactions resulting from new physics, as well as Weakly Interacting Massive Particles (WIMPs) with unconventional electronic recoils, are…

The GERDA (GERmanium Detector Array) experiment aiming to search for the neutrinoless double beta decay of 76Ge at the Laboratori Nazionali Del Gran Sasso (LNGS), Italy, will operate bare enriched high-purity germanium (HPGe) detectors in…

High-purity germanium crystals approximately 12 cm in diameter were grown in a hydrogen atmosphere using the Czochralski method. The dislocation density of the crystals was determined to be in the range of 2000 - 4200 cm-2, which meets a…

Instrumentation and Detectors · Physics 2015-05-08 Guojian Wang , Mark Amman , Hao Mei , Dongming Mei , Klaus Irmscher , Yutong Guan , Gang Yang

The China Dark Matter Experiment (CDEX) Collaboration will carry out a direct search for weakly interacting massive particles with germanium detectors. Liquid argon will be utilized as an anti-Compton and cooling material for the germanium…

Instrumentation and Detectors · Physics 2015-06-18 Ying-Shuai Du , Qian Yue , Yi-Bao Liu , Qing-Hao Chen , Jin LI , Jian-Ping Cheng , Ke-Jun Kang , Yuan-Jing Li , Yu-Lan Li , Hao Ma , Hao-Yang Xing , Xun-Zhen Yu , Zhi Zeng

Low-energy background through Compton scattering from the ambient $\gamma$ rays can be contaminated in direct dark matter search experiments. In this paper, we report comparable measurements on low-energy spectra via Compton scattering from…

Instrumentation and Detectors · Physics 2023-04-26 J. W. Hu , L. T. Yang , Q. Yue , X. P. Geng , H. B. Li , Y. F. Liang , S. T. Lin , S. K. Liu , H. Ma , L. Wang , H. T. Wong , B. T. Zhang

The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to…

Instrumentation and Detectors · Physics 2010-03-26 Christian Regenfus

To build upon the goals of the upcoming INTEGRAL mission, the next generation soft gamma-ray (0.2-20 MeV) observatory will require improved sensitivity to nuclear line emission while maintaining high spectral resolution. We present the…

Astrophysics · Physics 2007-05-23 Steven E. Boggs , Pierre Jean

As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The…

The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic…