Related papers: Scintillating double beta decay bolometers
In germanium-based light detectors for scintillating bolometers, a SiO$_2$ anti-reflective coating is often applied on the side of the germanium wafer exposed to light with the aim to improve its light collection efficiency. In this paper,…
The large statistics collected during the operation of a ZnMoO$_4$ array, for a total exposure of 1.3 kg $\cdot$ day of $^{100}$Mo, allowed the first bolometric observation of the two neutrino double beta decay of $^{100}$Mo. The observed…
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$\nu$2$\beta$ decay of $^{100}$Mo with the goal to set the basis for large scale…
The results of the experimental investigations of double beta processes in Zinc and Tungsten isotopes with the help of middle volume (117 g, 168 g and 699 g) low-background ZnWO_4 crystal scintillators are presented. The experiment was…
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed…
A new phase of 116Cd double beta decay experiment is in progress in the Solotvina Underground Laboratory. Four enriched 116CdWO4 scintillators with total mass 339 g are used in a set up, whose active shield is made of 15 natural CdWO4…
Double beta processes in 64-Zn, 70-Zn, 180-W, and 186-W have been searched for with the help of large volume (0.1-0.7 kg) low background ZnWO4 crystal scintillators at the Gran Sasso National Laboratories of the INFN. Total time of…
Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted…
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector…
PbWO4 crystal scintillators are discussed as an active shield and light-guides in 116Cd double beta decay experiment with CdWO4 scintillators. Scintillation properties and radioactive contamination of PbWO4 scintillators were investigated.…
Scintillator detectors can be used in experiments searching for neutrinoless double beta decay. A wide variety of double beta decay candidate isotopes can be made into scintillators or can be loaded into scintillators. Experimental programs…
Scintillating crystal detector offers potential advantages in low-energy low-background experiments for particle physics and astrophysics. The GSO crystal is an interesting detector to explore for future neutrino physics experiments. The…
The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors…
A new experiment based on tin-loaded scintillator is proposed to measure the 2nu double beta decay half-life of Sn-124 for the first time. Measurements of long term stabilitiy and optical properties of the produced scintillator are…
A convincing observation of neutrino-less double beta decay (0$\nu$DBD) relies on the possibility of operating high energy-resolution detectors in background-free conditions. Scintillating cryogenic calorimeters are one of the most…
A search for the double beta decay of zinc and tungsten isotopes has been performed with the help of radiopure ZnWO4 crystal scintillators (0.1-0.7 kg) at the Gran Sasso National Laboratories of the INFN. The total exposure of the low…
We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double-$\beta$ active isotope $^{100}$Mo (Li$_2$$^{100\textrm{depl}}$MoO$_4$). We used two…
Two neutrino double $\beta$ decay can create irremovable background even in high energy resolution detectors searching for neutrinoless double $\beta$ decay due to random coincidence of $2\nu2\beta$ events in case of poor time resolution.…
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected…
Bolometers are ideal devices in the search for neutrinoless Double Beta Decay. Enlarging the mass of individual detectors would simplify the construction of a large experiment, but would also decrease the background per unit mass induced by…