Related papers: A Current Mode Detector Array for Gamma-Ray Asymme…
This paper describes a new measurement of the flux ratio of positive and negative muons from cosmic-ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The…
Using the new results on coherent elastic neutrino-nucleus scattering data in cesium-iodide provided by the COHERENT experiment, we determine a new measurement of the average neutron rms radius of $^{133}\text{Cs}$ and $^{127}\text{I}$. In…
The CMS Zero Degree Calorimeters, ZDCs, will measure photons and neutrons emitted with |eta|> 8.6 from Pb+Pb, p+Pb and p+p collisions at sqrt(Snn)=5.5, 8.8 and 14 TeV respectively. The calorimeter consists of an electromagnetic part…
A measurement of the Z gamma to nu nu-bar gamma production cross section in pp collisions at sqrt(s) = 8 TeV is presented, using data corresponding to an integrated luminosity of 19.6 inverse femtobarns collected with the CMS detector at…
A novel design for an inexpensive depth of interaction capable detector for gamma rays, suitable for nuclear medical applications, especially Positron Emission Tomography, has been developed. The design takes advantage of the strong…
Differential cross section measurements of W$^\pm\gamma$ production in proton-proton collisions at $\sqrt{s}$ = 13 TeV are presented. The data set used in this study was collected with the CMS detector at the CERN LHC in 2016-2018 with an…
A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have…
PIXELATED geiger-mode avalanche photodiodes(PPDs), often called silicon photomultipliers (SiPMs) are emerging as an excellent replacement for traditional photomultiplier tubes (PMTs) in a variety of detectors, especially those for subatomic…
Far-infrared detectors for future cooled space telescopes require ultra-sensitive detectors with optical noise equivalent powers of order 0.2 aW/\sqrt Hz. This performance has already been demonstrated in arrays of transition edge sensors.…
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…
We report on the construction and upgrade of a Lawrence Berkeley National Laboratory Cosmic Muons Detector. We modify the electronics and mechanics to achieve a highly efficient gamma-ray and cosmic-ray detector. Each detector module uses a…
Novel NaIL detector (5x6 inch) was investigated for aims of neutron detection in wide energy range. It has been found that the detector together with its known ability to detect the {\gamma}- radiation is also allows to distinguish neutron…
We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture…
We propose an alternative approach for the detection of fast neutrons in the energy range from 10-4 to 5 MeV based on 10B-RPCs (hybrid double-gap Resistive Plate Chambers with 10B4C neutron converters) surrounded by a polyethylene…
In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time…
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray…
The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector…
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from…
Compton telescope is a promising technology to achieve very high sensitivity in the soft gamma-ray band (0.1-10 MeV) by utilizing Compton kinematics. Compton kinematics also enables polarization measurement which will open new windows to…