English
Related papers

Related papers: Study of neutron response and n-gamma discriminati…

200 papers

A VME-based experiment system for n-{\gamma} discrimination using the charge comparison method was established. A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed…

Instrumentation and Detectors · Physics 2015-06-17 Yonghao Chen , Ximeng Chen , Xiaodong Zhang , Jiarong Lei , Li An , Jianxiong Shao , Pu Zheng , Xinhua Wang , Chuanxin Zhu , Tie He , Jian Yang

The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape…

Instrumentation and Detectors · Physics 2016-11-02 J. Scherzinger , R. Al Jebali , J. R. M. Annand , K. G. Fissum , R. Hall-Wilton , K. Kanaki , M. Lundin , B. Nilsson , H. Perrey , A. Rosborg , H. Svensson

The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $\gamma$-ray tagging has been carried out for various radioactive $\gamma$-ray sources. The measured electron…

Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid…

A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using…

Nuclear Experiment · Physics 2009-01-16 P. C. Rout , D. R. Chakrabarty , V. M. Datar , Suresh Kumar , E. T. Mirgule , A. Mitra , V. Nanal , R. Kujur

The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV…

A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…

Instrumentation and Detectors · Physics 2014-11-24 T. J. Langford , C. D. Bass , E. J. Beise , H. Breuer , D. K. Erwin , C. R. Heimbach , J. S. Nico

We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a…

Instrumentation and Detectors · Physics 2019-10-23 A. Biekert , S. A. Hertel , E. Huebler , J. Lin , H. D. Pinckney , R. K. Romani , A. Serafin , V. Velan , D. N. McKinsey

The $^3$He(n,p) process is excellent for neutron detection between thermal and $\sim$4\,MeV because of the high cross section and near-complete energy transfer from the neutron to the proton. This process is typically used in gaseous forms…

Instrumentation and Detectors · Physics 2023-12-29 A. E. Sharbaugh , L. Jones , A. N. Villano

The response of the liquid scintillator array Nordball to neutrons in the energy range 1.5 < T_n < 10 MeV has been measured by time of flight using a 252Cf fission source. Fission fragments were detected by means of a thin-film plastic…

Instrumentation and Detectors · Physics 2009-11-11 A. Reiter

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…

Instrumentation and Detectors · Physics 2015-06-15 C. Zhang , D. -M. Mei , P. Davis , B. Woltman , F. Gray

A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the…

Instrumentation and Detectors · Physics 2015-12-09 Bo Wan , Xueying Zhang , Liang Chen , Honglin Ge , Fei Ma , Hongbin Zhang , Yongqin Ju , Yanbin Zhang , Yanyan Li , Xiaowei Xu

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks'…

A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and…

This tutorial is devoted to the understanding of the different components that are present in the neutron light output pulse height distribution of liquid scintillators in fusion relevant energy ranges. The basic mechanisms for the…

Instrumentation and Detectors · Physics 2018-10-16 M. Cecconello

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…

Instrumentation and Detectors · Physics 2022-10-20 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

We report observations from the (p,n) reaction on 12C at 135 MeV. The experiment was performed with the beam-swinger neutron time-of-flight system at the Indiana University Cyclotron Facility. Neutrons were detected in large-volume plastic…

The Compact Neutron Spectrometer (CNS) is a Joint European Torus (JET) Enhancement Project, designed for fusion diagnostics in different plasma scenarios. The CNS is based on a liquid scintillator (BC501A) which allows good discrimination…

Instrumentation and Detectors · Physics 2012-03-27 F. Gagnon-Moisan , M. Reginatto , A. Zimbal

Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…

Nuclear Experiment · Physics 2008-12-08 P. -A. Söderström , J. Nyberg , R. Wolters
‹ Prev 1 2 3 10 Next ›