English
Related papers

Related papers: High Resolution Heavy Ion Track Structure Imaging

200 papers

Energy levels, radiative rates and lifetimes are reported for 19 F-like ions with 55 $\le$ Z $\le$ 73, among 113 levels of the 2s$^2$2p$^5$, 2s2p$^6$, 2s$^2$2p$^4$3$\ell$, 2s2p$^5$3$\ell$, and 2p$^6$3$\ell$ configurations. The…

Atomic Physics · Physics 2019-05-22 K M Aggarwal

Transport of fast electron in overdense plasmas is of key importance in high energy density physics. However, it is challenging to diagnose the fast electron transport in experiments. In this article, we study coherent transition radiation…

This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the…

Instrumentation and Detectors · Physics 2025-06-11 ICARUS collaboration , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewic , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Baibussinov , B. Behera , V. Bellini , R. Benocci , J. Berger , S. Berkman , S. Bertolucci , M. Betancourt , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , D. Brailsford , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , A. Castro , S. Centro , G. Cerati , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chitirasreemadam , M. Cicerchia , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , A. A. Dange , A. de Roeck , S. Di Domizio , L. Di Noto , C. Di Stefano , D. Di Ferdinando , M. Diwan , S. Dolan , L. Domine , S. Donati , F. Drielsma , J. Dyer , S. Dytman , A. Falcone , C. Farnese , A. Fava , A. Ferrari , N. Gallice , F. G. Garcia , C. Gatto , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , H. Hausner , A. Heggestuen , B. Howard , R. Howell , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , D. P. Méndez , A. Menegolli , G. Meng , O. G. Miranda , A. Mogan , N. Moggi , E. Montagna , C. Montanari , A. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. Naples , V. C. L. Nguyen , S. Palestini , M. Pallavicini , V. Paolone , R. Papaleo , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , G. Riccobene , E. Richards , M. Rosenberg , M. Rossella , P. Roy , C. Rubbia , M. Saad , S. Saha , P. Sala , S. Samanta , P. Sapienza , A. Scaramelli , A. Scarpelli , D. Schmitz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , L. Stanco , J. Stewart , H. A. Tanaka , F. Tapia , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , R. Triozzi , Y. -T. Tsai , S. Tufanli , T. Usher , F. Varanini , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , Z. Williams , R. J. Wilson , P. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Wospakrik , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli

For the assessment of radiation effects of clinical ion-beams, dosimetry has to be complemented by information on particle-energy distribution or related quantities. Fluorescence nuclear track detectors made from C,Mg-doped alumina single…

Medical Physics · Physics 2017-09-22 Steffen Greilich , Leonie Ulrich , Jasper J. M. Kouwenberg , Shirin Rahmanian

The K x-ray spectra of different targets (Cu, Zn, and Ge) induced by 3 to 5 MeV/u Si projectile ions have been measured to determine the K-shell ionization cross-section. A significant difference is observed between the measurements and…

Atomic Physics · Physics 2021-08-18 Soumya Chatterjee , Prashant Sharma , Montanary Claudia , D. Mitra , T. Nandi

Accurate molecular imaging via high-order harmonic generation relies on comparing the harmonic emission from a molecule and an adequate reference system. However, an ideal reference atom with the same ionization properties as the molecule…

Atomic Physics · Physics 2015-05-28 Elmar V. van der Zwan , Manfred Lein

In this study, we report a physical model and a Monte Carlo simulation scheme developed to predict the angular distributions of energetic argon atoms and ions as an ion beam passes through a gas-filled volume. The study explores…

Plasma Physics · Physics 2026-04-10 Alexander V. Khrabrov , Igor D. Kaganovich

Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be…

We propose intensity interferometry with identical lepton pairs as an efficient tool for the estimation of the source size of the expanding hot zone produced in relativistic heavy ion collisions. This can act as a complementary method to…

Nuclear Theory · Physics 2009-11-10 Jan-e Alam , Bedangadas Mohanty , A. Rahaman , Sourav Sarkar , Bikash Sinha

We present a largely improved version of CRASH, a 3-D radiative transfer code that treats the effects of ionizing radiation propagating through a given inhomogeneous H/He cosmological density field, on the physical conditions of the gas.…

Astrophysics · Physics 2009-11-10 A. Maselli , A. Ferrara , B. Ciardi

We consider theoretically the energy loss of electrons scattered to high angles when assuming that the primary beam can be limited to a single atom. We discuss the possibility of identifying the isotopes of light elements and of extracting…

Instrumentation and Detectors · Physics 2015-05-06 G. Argentero , C. Mangler , J. Kotakoski , F. R. Eder , J. C. Meyer

The heavy ion physics approach to global event characterization has led us to instrument the forward region in the PHENIX experiment at RHIC. In heavy ion collisions this coverage yields a measurement of the "spectator" energy and its…

Nuclear Experiment · Physics 2008-11-26 Sebastian N. White

The so called "isobar run" or RHIC was designed to compare a number of observables for collisions of $^{96}_{40}Zr$ with those of $^{96}_{44}Ru$, aimed at identification of $Z$-dependent effects. However, as the STAR data have shown with…

Nuclear Theory · Physics 2022-02-09 Edward Shuryak

Scanning transmission electron microscopy (STEM) has advanced rapidly in the last decade thanks to the ability to correct the major aberrations of the probe forming lens. Now atomic-sized beams are routine, even at accelerating voltages as…

A compact time projection chamber (TPC) prototype was studied for charged-pion tracking in the annihilation detector proposed for the HIBEAM experiment at the European Spallation Source. HIBEAM aims to search for neutron-antineutron…

Instrumentation and Detectors · Physics 2026-05-28 Blahoslav Rataj , Valentina Santoro , Anders Oskarsson , Matthias Holl , Verena Hehl , David Silvermyr

In this paper, energy levels, radiative rates and lifetimes are reported for 11 F-like ions with 12 $\le$ Z $\le$ 23. Up to 198 levels (depending on the ion) have been considered which include 113 of the 2s$^2$2p$^5$, 2s2p$^6$,…

Atomic Physics · Physics 2019-01-16 K M Aggarwal

Simulations of radiation damage in single molecule imaging using a X-ray free electron laser use atomic rates calculated in the lowest order. We investigate the difference in ion yield predictions using Hartree-Fock and Hartree-Fock-Slater…

Atomic Physics · Physics 2019-05-22 Alexander Kozlov , Harry M. Quiney

Different techniques of the X-ray Diffraction Line Profile Analysis (XRDLPA) have been used to assess the microstructure of the irradiated Zr-1.0%Nb-1.0%Sn-0.1%Fe alloy. The domain size, microstrain, density of dislocation and the stacking…

Materials Science · Physics 2007-05-23 A. Sarkar , P. Mukherjee , P. Barat

The energy spread of a focused ion beam causes chromatic aberration that limits the focal spot size and resolution for imaging and fabrication. Ion beams based on photoionization of neutral atoms can have a much smaller energy spread and…

Standard dosimetry protocols exist for highly penetrating photon and particle beams used in the clinic and in research. However, these protocols cannot be directly applied to shallow penetration MeV-range ion beams. The Radiological…

Accelerator Physics · Physics 2022-02-23 Guy Garty , Andrew D. Harken , David J. Brenner
‹ Prev 1 4 5 6 7 8 10 Next ›