English
Related papers

Related papers: Optical Alignment System for the PHENIX Muon Track…

200 papers

The CMS silicon tracking system measures the trajectories of charged particles with a hit resolution of the order of microns in the pixel detector and tens of microns in the strip detector. One of the most important inputs for track…

Instrumentation and Detectors · Physics 2023-03-30 Ana Ventura Barroso

For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the…

Instrumentation and Detectors · Physics 2016-10-04 M. Deile , H. Dietl , J. Dubbert , S. Horvat , O. Kortner , H. Kroha , A. Manz , S. Mohrdieck , F. Rauscher , R. Richter , A. Staude

Maintaining optical alignment between stations of a free-space optical link requires a persistent beam tracking operation. This is achieved using a position-sensitive photodetector at each station which measures the azimuth and elevation of…

Optimization and Control · Mathematics 2007-05-23 Arash Komaee

The CMS silicon tracker, consisting of 1440 silicon pixel and 15148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last four years. This spectrometer will use pressurized Monitored Drift Tube (MDT) chambers and Cathode Strip Chambers…

Instrumentation and Detectors · Physics 2008-11-26 Erez Etzion

A set of classical multi-wire proportional chambers were designed and constructed with the main purpose of efficient cosmic muon detection. These detectors are relatively simple to construct, and at the same time are low cost, making them…

Instrumentation and Detectors · Physics 2015-09-30 Dezső Varga , Zoltán Gál , Gergő Hamar , Janka Sára Molnár , Éva Oláh , Péter Pázmándi

In operating rooms (OR), world-scale multi-view 3D tracking supports downstream applications such as surgeon behavior recognition, where physically meaningful quantities such as distances and motion statistics must be measured in meters.…

Computer Vision and Pattern Recognition · Computer Science 2026-03-03 Yihua Shao , Kang Chen , Feng Xue , Siyu Chen , Long Bai , Hongyuan Yu , Hao Tang , Jinlin Wu , Nassir Navab

The inner silicon detector of the Compact Muon Solenoid experiment (CMS) at CERN's LHC consists of 16588 modules. Charged-particle tracks in the detector are used to improve the accuracy to which the position and orientation of the modules…

Instrumentation and Detectors · Physics 2015-05-27 Volker Blobel , Claus Kleinwort , Frank Meier

Clinical tracking systems are popular but typically require specific tracking markers. During the last years, scanning speed of optical coherence tomography (OCT) has increased to A-scan rates above 1 MHz allowing to acquire volume scans of…

Medical Physics · Physics 2019-01-15 Matthias Schlüter , Christoph Otte , Thore Saathoff , Nils Gessert , Alexander Schlaefer

Organized Autotelescopes for Serendipitous Event Survey (OASES) is an optical observation project that aims to detect and investigate stellar occultation events by kilometer-sized trans-Neptunian objects (TNOs). In this project, multiple…

Instrumentation and Methods for Astrophysics · Physics 2017-09-20 Ko Arimatsu , Kohji Tsumura , Kohei Ichikawa , Fumihiko Usui , Takafumi Ootsubo , Takayuki Kotani , Yuki Sarugaku , Takehiko Wada , Koichi Nagase , Jun-ichi Watanabe

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

Non-central heavy ion collisions generate large orbital angular momentum (OAM), providing opportunities to study spin phenomena such as the global spin alignment of vector mesons. Such studies are expected to reveal properties of the…

Nuclear Experiment · Physics 2025-08-27 C. W. Robertson , Yicheng Feng , Fuqiang Wang

A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons…

Instrumentation and Detectors · Physics 2010-05-12 A. Ahmad , A. Andreazza , T. Atkinson , J. Baines , A. J. Barr , R. Beccherle , P. J. Bell , J. Bernabeu , Z. Broklova , P. A. Bruckman de Renstrom , D. Cauz , L. Chevalier , S. Chouridou , M. Citterio , A. Clark , M. Cobal , T. Cornelissen , S. Correard , M. J. Costa , D. Costanzo , S. Cuneo , M. Dameri , G. Darbo , J. B. de Vivie , B. Di Girolamo , D. Dobos , Z. Drasal , J. Drohan , K. Einsweiler , M. Elsing , D. Emelyanov , C. Escobar , K. Facius , P. Ferrari , D. Fergusson , D. Ferrere , T. Flick , D. Froidevaux , G. Gagliardi , M. Gallas , B. J. Gallop , K. K. Gan , C. Garcia , I. L. Gavrilenko , C. Gemme , P. Gerlach , T. Golling , S. Gonzalez-Sevilla , M. J. Goodrick , G. Gorfine , T. Goettfert , J. Grosse-Knetter , P. H. Hansen , K. Hara , R. Hartel , A. Harvey , R. J. Hawkings , F. E. W. Heinemann , T. Henns , J. C. Hill , F. Huegging , E. Jansen , J. Joseph , M. Karagoz Unel , M. Kataoka , S. Kersten , A. Khomich , R. Klingenberg , P. Kodys , T. Koffas , N. Konstantinidis , V. Kostyukhin , C. Lacasta , T. Lari , S. Latorre , C. G. Lester , W. Liebig , A. Lipniacka , K. F. Lourerio , M. Mangin-Brinet , S. Marti i Garcia , M. Mathes , C. Meroni , B. Mikulec , B. Mindur , S. Moed , G. Moorhead , P. Morettini , E. W. J. Moyse , K. Nakamura , P. Nechaeva , K. Nikolaev , F. Parodi , S. Parzhitski , J. Pater , R. Petti , P. W. Phillips , B. Pinto , A. Poppleton , K. Reeves , I. Reisinger , P. Reznicek , P. Risso , D. Robinson , S. Roe , A. Rozanov , A. Salzburger , H. Sandaker , L. Santi , C. Schiavi , J. Schieck , J. Schultes , A. Sfyrla , C. Shaw , F. Tegenfeldt , C. J. W. P. Timmermans , B. Toczek , C. Troncon , M. Tyndel , F. Vernocchi , J. Virzi , T. Vu Anh , M. Warren , J. Weber , M. Weber , A. R. Weidberg , J. Weingarten , P. S. Wells , A. Zhelezko

Alignment-based optically pumped magnetometers (OPMs) are capable of measuring oscillating magnetic fields with high sensitivity in the fT/sqrt(Hz) range. Until now, alignment-based magnetometers have only used paraffin-coated vapour cells…

Applied Physics · Physics 2023-06-30 L. M. Rushton , L. Elson , A. Meraki , K. Jensen

Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic…

This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of…

For most physical processes the tracks observed in the muon stations must be matched with the corresponding tracks in the inner tracker, the external muon system providing muon identification and triggering but the tracker points giving the…

High Energy Physics - Experiment · Physics 2016-08-31 A. Benvenuti , D. Denegri , V. Genchev , A. Khanov , N. Stepanov , P. Vankov

A high-precision silicon microstrip detector assembly methodology based on a gantry system is presented in this paper. The proposed approach has been applied to the mass production of all flight-model detector modules for the L0 tracking…

High Energy Physics - Experiment · Physics 2025-09-30 Feng Wang , Xuhao Yuan

The alignment of tracking detectors is crucial for the physics programme at the LHC, especially for precision measurements like the W mass. The alignment of the ATLAS silicon tracking detectors with a total of 5832 modules poses an…

Instrumentation and Detectors · Physics 2008-08-05 Oleg Brandt

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger