Related papers: Sparticle Masses from Kinematic Fitting at a Muon …
Accurate measurements of particles masses, couplings and widths are possible by measuring production cross sections near threshold. We discuss the prospects for performing such measurements at a high luminosity muon collider.
To measure the muon decay parameters with high accuracy, we require an array of precision drift detector layers whose relative position is known with very high accuracy. This article describes the design, construction and performance of…
The first chapter serves as an introduction to the MSSM. I briefly review the model and explain why stops and sbottoms provide an interesting playground for exploring and testing this model. In the second chapter I discuss stop and sbottom…
Strong quantum zero-point motion (ZPM) of light nuclei and other particles is a crucial aspect of many state-of-the-art quantum materials. However, it has only recently begun to be explored from an $\textit{ab initio}$ perspective, through…
The Compact Muon Solenoid (CMS) is fully equipped to measure leptonic decays of electroweak probes in the high multiplicity environment of nucleus-nucleus collisions. Electroweak boson production is an important benchmark process at hadron…
Future lepton colliders, such as those based on linear $e^+e^-$ or circular $\mu^+\mu^-$ accelerators, are expected to attain centre-of-mass energies in the multi-TeV range. In this regime the impact of QED and of weak radiation, in both…
Precision measurement of the stop mass at the ILC is done in a method based on cross-sections measurements at two different center-of-mass energies. This allows to minimize both the statistical and systematic errors. In the framework of the…
We present a set of Lorentz invariant kinematic variables for reconstructing mass of semi-invisible decaying particles pair-produced at lepton colliders, $m_{\rm RC}^{\rm min}$, $m_{\rm RC}^{\rm max}$ and $m_{\rm LSP}^{\rm max}$, with…
The hit response of silicon vertex and tracking detectors to muon collider beam background and results of a study of hit reducing techniques are presented. The background caused by decays of the 750 GeV/c m+ and m- beams was simulated using…
The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System…
The procedures for studying a single narrow s-channel resonance or nearly degenerate resonances at a lepton collider, especially a muon collider, are discussed. In particular, we examine four methods for determining the parameters of a…
The determination of the smuon mass at the CLIC multi-TeV e+e- linear collider has been studied for two CMSSM benchmarks. Results are given for both the analysis of the muon energy spectrum and the threshold scan method. The effects of…
The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton…
For most physical processes the tracks observed in the muon stations must be matched with the corresponding tracks in the inner tracker, the external muon system providing muon identification and triggering but the tracker points giving the…
The $4.2\sigma$ discrepancy in the $(g-2)$ of the muon provides a hint that may indicate that physics beyond the standard model is at play. A multi-TeV scale muon collider provides a natural testing ground for this physics. In this paper,…
In a supersymmetric model, the presence of a right handed neutrino with a large Yukawa coupling $f_{\nu}$ would affect slepton masses via its contribution to the renormalization group evolution between the grand unification and weak scales.…
We construct a new gauged $U(1)_\ell$ lepton number model which is anomaly-free for each SM generation. The active neutrino masses are radiatively generated with a minimal scalar sector. The phenomenology and collider signals are studied.…
It is generally accepted that experiments at an e+e- linear colliders will be able to extract the masses of the selectron as well as the associated sneutrinos with a precision of ~ 1% by determining the kinematic end points of the energy…
Muon colliders provide an exciting new direction to expand the energy frontier of particle physics. We point out a new use of these facilities for neutrino and beyond the Standard Model physics using their main detectors. Muon decays along…
In muon spin rotation experiments the positive implanted muon vibrates with large zero point amplitude by virtue of its light mass. Quantum mechanical calculations of the host material usually treat the muon as a point impurity, ignoring…