Related papers: Coherent Betatron Oscillation and Induced Errors i…
The electric field corrections to the recently measured muon magnetic moment g-2 anomaly are considered from both the classical (BMT) and the quantum mechanical (Dirac) viewpoints. In both views, we prove that the electric field inducing…
A new experiment to measure the muon g-2 factor is proposed. We suppose the sensitivity of this experiment to be about 0.03 ppm. The developed experiment can be performed on an ordinary storage ring with a noncontinuous field created by…
A precision measurement of the anomalous magnetic moment (g-2) of the muon has been made by the E821 collaboration at BNL. This paper is a written version of a ``hot topics'' talk at ICAP2002 (Cambridge, MA). The principles of the…
The muon anomalous magnetic moment is one of the most precisely measured quantities in particle physics. In a recent experiment at Brookhaven it has been measured with a remarkable 14-fold improvement of the previous CERN experiment…
In a recent experimental paper reporting a precise measurement of the muon anomalous magnetic moment, Brown et al. claim disagreement of their result with evaluations based on the standard model. This claim is based on comparison with a…
The muon anomalous magnetic moment is one of the most precisely measured quantities in particle physics. Recent high precision measurements (0.54ppm) at Brookhaven reveal a ``discrepancy'' by 3 standard deviations from the electroweak…
The longstanding discrepancy between the measured and the predicted values of the anomalous magnetic moment of the muon, $a_\mu = (g-2)/2$, is one of the most intriguing potential hints of new physics in particle physics. After a brief…
A review of the experimental and theoretical determinations of the anomalous magnetic moment of the muon is given. The anomaly is defined by a=(g-2)/2, where the Land\'e g-factor is the proportionality constant that relates the spin to the…
The Fermi National Accelerator Laboratory (FNAL) Muon $g-2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics…
The anomalous magnetic moments of both positive and negative muons are measured to the precision of 0.7 parts per million. Two values are in good agreement. The standard model calculations of muon g-2 are under further studies, especially…
This article reviews the muon g-2 experiment, a cornerstone in precision tests of the Standard Model of particle physics. The experiment measures the anomalous magnetic moment of the muon with unprecedented accuracy, seeking potential…
The anomalous magnetic moment (g-2) of the muon was measured with a precision of 0.54 ppm in Experiment 821 at Brookhaven National Laboratory. A difference of 3.2 standard deviations between this experimental value and the prediction of the…
The Muon g-2 collaboration has measured the anomalous magnetic g value, a = (g-2)/2, of the positive muon with an unprecedented uncertainty of 0.7 parts per million. The result, based on data collected in the year 2000 at Brookhaven…
This work demonstrates that two systematic errors, coherent betatron oscillations (CBO) and muon losses can be reduced through application of radio frequency (RF) electric fields, which ultimately increases the sensitivity of the muon $g-2$…
The Fermilab Muon $g-2$ experiment measures the muon anomalous magnetic moment with high precision. Together with recent improvements on the theory front, the first results of the experiment confirm the long-standing discrepancy between the…
No gauge invariant regularization is available for the perturbative calculation of the standard model. One has to add finite counter terms to restore gauge symmetry for the renormalized amplitudes. The muon anomalous magnetic moment can be…
The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
We present a summary of the results of two recent precise calculations of the muon anomalous magnetic moment ($g_{\mu}-2$) and the electromagnetic coupling on the $Z$ ($\bar{\alpha}_{\rm Q.E.D.}(M^2_{Z})$). The main sources of uncertainty…
The very precise measurement of the anomalous magnetic moment of the muon, recently released by the Muon g-2 experiment at Fermilab, can serve to set stringent constraints on new particles. If the observed 4$\sigma$ discrepancy from the…
The muon (g-2) experiment at Brookhaven National Laboratory has measured the anomalous magnetic moment of the positive muon with a precision of 0.7 ppm. This paper presents that result, concentrating on some of the important experimental…