Related papers: Current Performance of the SLD VXD3
Charge Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellite over the past two decades. Their high energy resolution and high spatial resolution make them an perfect tool for low energy…
DEPFET active pixel sensors are a well-developed technology for vertex detectors at future colliders. Extensive test beam campaigns have proven the excellent performance of these devices, and their radiation hardness has been thoroughly…
The past ten years have seen the advent of silicon-based precise timing detectors for charged particle tracking. The underlying reason for this evolution is a design innovation: the Low-Gain Avalanche Diode (LGAD). In its simplicity, the…
The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…
We report a new measurement of A_b using data obtained by SLD in 1997-98. This measurement uses a vertex tag technique, where the selection of a b hemisphere is based on the reconstructed mass of the bottom hadron decay vertex. The method…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The Belle-II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8 x 10^35 cm-2 s-1 achievable by the new SuperKEKB e+e- collider, now under commissioning at the KEK laboratory…
A Scintillator Deposited CCD (SDCCD) is a wide-band X-ray detector consisting of a CCD and a scintillator directly attached to each other. We assembled the newly developed SDCCD that the scintillator CsI(Tl) is below the fully depleted CCD.…
CLIC is a proposed linear $e^{+}e^{-}$ collider with center-of-mass energies of up to $3\,\textrm{TeV}$. Its main objectives are precise top quark and Higgs boson measurements, as well as searches for Beyond Standard Model physics. To meet…
Significant progress has been made to develop silicon pixel technologies for use in the vertex and tracker regions of the proposed Compact Linear Collider (CLIC) detector design. The electron-positron collisions generated by this linear…
The R&D Collaboration SiLC (Silicon tracking for Linear Colliders) is based on generic R&D aiming to develop the next generation of large Silicon tracking systems for the Linear collider experiments; it serves all three ILC detector…
I summarise the status of the LCFI Collaboration R&D programme for a CCD-based vertex detector for the linear collider.
This paper reports the last technological development on the Low Gain Avalanche Detector (LGAD) and introduces a new architecture of these detectors called inverse-LGAD (iLGAD). Both approaches are based on the standard Avalanche Photo…
We compare heavy quark tagging and anti-tagging efficiencies for vertex detectors with different inner raddi using the topological vertex technique developed at the SLC/SLD experiment. Charm tagging benefits by going to very small inner…
This paper presents a study of vertex tracking with a beam hodoscope consisting of three layers of monolithic pixel sensors in SOI technology on high-resistivity substrate. We study the track extrapolation accuracy, two-track separation and…
The Semiconductor Tracker (SCT) is a silicon strip detector and one of the key precision tracking devices in the Inner Detector of the ATLAS experiment at CERN LHC. The completed SCT has been installed inside the ATLAS experimental cavern…
CLIC is a proposed linear $e^+e^-$ collider with center-of-mass energies of up to 3 TeV. Its main objectives are precise top quark, Higgs boson and Beyond Standard Model physics. In addition to spatial resolutions of a few micrometers and a…
Superconducting Digital (SCD) technology offers significant potential for enhancing the performance of next generation large scale compute workloads. By leveraging advanced lithography and a 300 mm platform, SCD devices can reduce energy…
One of the major physics goals at the ILC is the precise measurement of the Higgs coupling constants to b-quarks and c-quarks. To achieve this measurement, we need a high-performance vertex detector leading to precise flavor tagging. For…
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout…