English
Related papers

Related papers: Medium energy calorimetry at SND: techniques and p…

200 papers

The Spherical Neutral Detector (SND) operates at VEPP-2M collider in Novosibirsk studying e^+e^- annihilation in the energy range up to 1.4 GeV. Detector consists of a fine granulated spherical scintillation calorimeter with 1632 NaI(Tl)…

The SND is a non-magnetic detector deployed at the VEPP-2000 $e^+e^-$ collider (BINP, Novosibirsk) for hadronic cross-section measurements in the center of mass energy region below 2 GeV. The important part of the detector is a three-layer…

The general purpose spherical nonmagnetic detector (SND) is now taking data at VEPP-2M $e^+e^-$ collider in BINP (Novosibirsk) in the centre of mass energy range of $0.2 \div 1.4$ GeV. The energy calibration of the NaI(Tl) calorimeter of…

Instrumentation and Detectors · Physics 2009-10-31 M. N. Achasov , A. D. Bukin , D. A. Bukin , V. P. Druzhinin , V. B. Golubev , V. N. Ivanchenko , S. V. Koshuba , S. I. Serednyakov

The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a…

Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.

Instrumentation and Detectors · Physics 2009-10-31 M. N. Achasov , D. A. Bukin , T. V. Dimova , V. P. Druzhinin , V. B. Golubev , V. N. Ivanchenko , A. A. Korol

The current status of experiments with SND detector at VEPP-2M e^+e^- collider in the energy range 2E_0=400-1400 MeV and recent results of data analysis for $\phi$, $\omega$ and $\rho$ decays and e^+e^- annihilation into hadrons are…

The program of upgrade of the Spherical Neutral Detector for future experiments at a new VEPP-2000 $e^+e^-$ collider is presented. Modernization includes upgrades of electromagnetic calorimeter, tracking system, detector electronics, data…

The Multi-Purpose Detector (MPD) is designed to study a hot and dense baryonic matter formed in heavy-ion collisions at SQRT(sNN)=4-11 GeV at the NICA accelerator complex (Dubna, Russia). Large-sized electromagnetic calorimeter (ECal) of…

This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector which is…

Instrumentation and Detectors · Physics 2017-03-08 A. A. Korol , N. A. Melnikova

A dual-operation mode SNSPD is proposed. In the conventional Geiger mode, the sensor operates at temperatures well below the critical temperature, Tc, working as an event counter without sensitivity to the number of photons impinging the…

SND@LHC is a compact and stand-alone experiment designed to perform measurements with neutrinos produced at the LHC in the pseudo-rapidity region of ${7.2 < \eta < 8.4}$. The experiment is located 480 m downstream of the ATLAS interaction…

High Energy Physics - Experiment · Physics 2024-07-08 LHC Collaboration

We explore the use of microstructured semiconductor neutron detectors (MSNDs) to map the ratio between thermal neutrons and higher energy neutrons. The system consists of alternating layers of modular neutron detectors (MNDs), each…

Instrumentation and Methods for Astrophysics · Physics 2020-04-22 Alejandro Soto , Ryan G. Fronk , Kerry Neal , Bent Ehresmann , Steven L. Bellinger , Michael Shoffner , Douglas S. McGregor

The results of the measurement of the $e^+e^- \to n \bar{n}$ cross section and effective neutron timelike form factor are presented. The data taking was carried out in 2020-2021 at the VEPP-2000 $e^+e^-$ collider in the center-of-mass…

The technique of discrimination of the $e^+e^-\to e^+e^-$ and $e^+e^-\to \pi^+\pi^-$ events in energy range $0.5 < \sqrt{s} < 1$ GeV by energy deposition in the calorimeter of SND detector was developed by applying machine learning method.…

Instrumentation and Detectors · Physics 2017-02-01 M. N. Achasov , K. I. Beloborodov , A. S. Kupich

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…

The review of experimental results obtained with SND detector at VEPP-2M $e^+e^-$ collider in the energy region $\sqrt[]{s}=0.36$ -- 1.38 GeV is given. The presented results include the following items: studies of the light vector mesons…

The fast development of superconducting nanowire single photon detector (SNSPD) in the past decade has enabled many advances in quantum information technology. The best system detection efficiency (SDE) record at 1550 nm wavelength was 93%…

Superconductivity · Physics 2017-10-16 W. J. Zhang , L. X. You , H. Li , J. Huang , C. L. Lv , L. Zhang , X. Y. Liu , J. J. Wu , Z. Wang , X. M. Xie

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

‹ Prev 1 2 3 10 Next ›