Related papers: Momentum Resolution Studies for a large TPC-Based …
The track timing capabilities of a silicon drift detector based tracker for a future linear electron-positron collider are evaluated. We show such a detector can time tracks at the nanosecond, and for high-$P_{T}$, sub-nanosecond level.…
The proposed Circular Electron Positron Collider (CEPC) imposes new challenges for the vertex detector in terms of pixel size and material budget. A Monolithic Active Pixel Sensor (MAPS) prototype called TaichuPix, based on a column drain…
An electron-positron linear collider in the energy range between 500 and 1000 GeV is of crucial importance to precisely test the Standard Model and to explore the physics beyond it. The physics program is complementary to that of the Large…
We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results of preliminary…
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…
A novel charged particle tracking device, a high precision time projection chamber with gas electron multiplier and pad readout, is a leading candidate as the central tracker for an experiment at the International Linear Collider. To…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…
The Technical Design Report (TDR) of the ILC mainly concentrates on a baseline machine of 500 GeV centre-of-mass with detailed cost and manpower estimates consistent with this option. However, the discovery of a Higgs Boson with a mass of…
This document outlines a community-driven Design Study for a 10 TeV pCM Wakefield Accelerator Collider. The 2020 ESPP Report emphasized the need for Advanced Accelerator R\&D, and the 2023 P5 Report calls for the ``delivery of an end-to-end…
CLIC is a proposed linear $e^+e^-$ collider with center-of-mass energies of up to 3 TeV. Its main objectives are precise top quark, Higgs boson and Beyond Standard Model physics. In addition to spatial resolutions of a few micrometers and a…
A method is described for estimating muon track momentum from the distribution of hits along tracks in dense calorimeters due to multiple Coulomb scattering (MCS). The method requires only well-aligned conventional drift chambers or similar…
The specific energy loss (dE/dx) resolution is critical for particle identification and separation in TPC. In connection with the R&D for the TPC at the Circular Electron Positron Collider (CEPC), we find the laser ionisation obeys the…
This work is dedicated to the study of a technique for hadron identification in the TeV momentum range, based on the simultaneous measurement of the energies and of the emission angles of the Transition Radiation (TR) X-rays with respect to…
The ATLAS detector has been designed to have good muon momentum resolution up to momenta in the TeV range. The muon momentum resolution of the ATLAS spectrometer has been measured with p-p collision data recorded in 2011. The measurement…
The existence of Majorana neutrinos must lead to lepton-number violating processes, and the Majorana nature of neutrinos can only be experimentally verified via lepton-number violating processes. We propose a new approach to search for…
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…
Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to…
We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5 GeV electron beam at DESY. Different GEM orientations and geometries were…
The TORCH time-of-flight detector will provide particle identification between 2-10 GeV/c momentum over a flight distance of 10 m, and is designed for large-area coverage, up to 30 m^2. A 15 ps time-of-flight resolution per incident…
P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from…