Related papers: Particle Identification with BELLE
Two modules of the AD detector have been studied with the test beam at the T10 facility at CERN. The AD detector is made of scintillator pads read out by wave-length shifters (WLS)coupled to clean fibres that carry the produced light to…
The Belle II experiment at the SuperKEKB collider in Tsukuba, Japan, will start physics data taking in 2018. It is planned to accumulate an e+ e- collision data set of 50 /ab, about 50 times larger than that of the earlier Belle experiment.…
Using a test TPC, consisting of the ALICE TPC field cage prototype in combination with the final ALICE TPC readout and electronics, the energy loss distribution and resolution were measured for identified protons. The measurements were…
The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator…
The charged particle multiplicity distribution is one of the first measurements that ALICE will be able to perform. The knowledge of this basic property at a new energy is needed to configure Monte Carlo generators correctly with the aim of…
The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…
(Gd,La)$_2$Si$_2$O$_7$:Ce (La-GPS:Ce) is a new scintillator material with high light output, high energy resolution, and fast decay time. Moreover, the scintillator has a good light output even at high temperature (up to 150$^\circ$C) and…
The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained…
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) near GSI, Darmstadt, Germany will address fundamental questions of hadron physics. Excellent Particle Identification (PID) over…
We have developed a detailed Monte Carlo simulation program for the Belle TOF system. Based on GEANT simulation, it takes account of all physics processes in the TOF scintillation counters and readout electronics. The simulation reproduces…
This review traces the evolution of precision timing in particle physics experiments, from the first large-scale applications of scintillator and photomultiplier tube (PMT) systems in the 1990s to the picosecond-precision detectors of…
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by…
The paper reviews recent progress in particle identification methods. A survey of motivations and requirements for particle identification in various experimental environments is followed by the main emphasis, which is on the recent…
The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technologies which can achieve fine granularity required for the particle flow algorithm. Second prototype of the ScECAL has been built and tested with…
We present a track-finding algorithm for the Belle II experiment that specifically targets so-called kinks: signatures of charged particles decaying or scattering in-flight in the detector material, resulting in a sudden and significant…
The Belle detector operated at KEKb B-factory in 1999-2010 was one of the most remarkable experiments in the field of elementary particle physics of the last decades. The Belle successor, Belle II collaboration, is aimed to operate the…
The ALICE detector was designed to track and identify particles in a wide transverse momentum range, from more than 100 GeV/c down to ~100 MeV/c. The innermost barrel-like detector, the Inner Tracking System (ITS), is dedicated to precise…
Particle-in-Cell Monte Carlo simulations on large-scale systems play a fundamental role in understanding the complexities of plasma dynamics in fusion devices. Efficient handling and analysis of vast datasets are essential for advancing…
The Multipurpose Detector (MPD) consists of a typical array of sub-detectors to study the nuclear matter originating from the collisions of beams provided by the Nuclotron-based Ion Collider fAcility (NICA). A beam monitoring…
Particle-in-Cell (PIC) simulation codes have wide applicability to first-principles modeling of multidimensional nonlinear plasma phenomena, including wake-field accelerators. This review addresses both finite difference and pseudo-spectral…