English
Related papers

Related papers: The CLEO-III Ring Imaging Cherenkov Detector

200 papers

We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the…

CLEO III upgrade was completed with the integration of Ring Imaging CHerenkov(RICH) detector for charged particle identification. The design of this cylindrical detector consists of LiF crystal radiators and multi-wire proportional chamber…

High Energy Physics - Phenomenology · Physics 2009-10-31 Gobinda Majumder

We describe the particle identification capability of the CLEO RICH system. This system consists of a 1 cm thick LiF radiator coupled to a photon detector that uses wire proportional chambers filled with a mixture of CH$_4$ and TEA. We…

Instrumentation and Detectors · Physics 2019-08-14 R. Sia

The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH$_4$ and TEA gases. The first two photon detector modules which were…

The CLEO detector has been upgraded to include a state of the art particle identification system, based on the Ring Imaging Cherenkov Detector (RICH) technology, in order to take data at the upgraded CESR electron positron collider. The…

High Energy Physics - Experiment · Physics 2009-10-31 M. Artuso , R. Ayad , A. Efimov , S. Kopp , G. Majumder , R. Mountain , S. Schuh , T. Skwarnicki , S. Stone , G. Viehhauser , J. Wang , S. Anderson , Y. Kubota , A. Smith , T. Coan , V. Fadeyev , J. Ye

We show that a multifaceted LiF radiator produces more Cherenkov light and has better resolution per photon than a flat radiator slab when used in a ring imaging Cherenkov counter. Such a system is being considered for the CLEO III upgrade.

High Energy Physics - Experiment · Physics 2010-11-01 A. Efimov , M. Artuso , Min Gao , R. Mountain , F. Muheim , Y. Mukhin , S. Playfer

We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel…

We describe the two major components of CLEO III: the Silicon Vertex Detector and the Ring Imaging Cherenkov Detector (RICH). The Silicon Vertex Detector is a four layer barrel-style device which spans the radial distance from 2.5 cm to…

High Energy Physics - Experiment · Physics 2007-05-23 Marina Artuso

The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a…

Instrumentation and Detectors · Physics 2010-09-14 A. Breskin , V. Peskov , A. Di Mauro , P. Martineng , D. Mayani Paras , L. Molnar , E. Nappi , G. Paic , J. van Hoorne

The performance of a prototype Ring Imaging Cherenkov Detector is studied using a charged particle beam. The detector performance, using CF4 and air as radiators, is described. Cherenkov angle precision and photoelectron yield using hybrid…

The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator…

A dedicated R\&D is ongoing for the charged particle identification system of the \mbox{ALICE 3} experiment proposed for the LHC Run 5 and beyond. One of the subsystems for the high-energy charged particle identification will be a…

The LHCb detector will be upgraded to make more efficient use of the available luminosity at the LHC in Run III and extend its potential for discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb detector for…

The CLEO detector will undergo major improvements in conjunction with a high luminosity upgrade of the CESR electron positron collider, that should increase the luminosity of this machine by a factor of 10. The most innovative feature of…

High Energy Physics - Experiment · Physics 2008-11-26 Marina Artuso

We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes.…

We briefly describe the design, construction and performance of the LiF-Tea RICH detector built to identify charged particles in the CLEO III experiment. Excellent pion/kaon separation is demonstrated.

The CLEO detector at the Cornell Electron Storage Ring (CESR) is completing a major upgrade that significantly extends its physics reach in the study of heavy quarks and leptons. The major elements of this detector upgrade are the…

High Energy Physics - Experiment · Physics 2009-10-31 Thomas Coan

The ALICE Collaboration is proposing a completely new apparatus, ALICE~3, for the LHC Runs~5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov…

Using aerogel as radiator and multianode PMTs for photon detection, a proximity focusing Cherenkov ring imaging detector has been constructed and tested in the KEK $\pi$2 beam. The aim is to experimentally study the basic parameters such as…

High Energy Physics - Experiment · Physics 2009-01-09 I. Adachi , I. Bizjak , A. Gorisek , T. Iijima , M. Iwamoto , S. Korpar , P. Krizan , R. Pestotnik , M. Staric , A. Stanovnik , T. Sumiyoshi , K. Suzuki , T. Tabata

A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index…

‹ Prev 1 2 3 10 Next ›