English
Related papers

Related papers: The Micro Wire Detector

200 papers

Gaseous detectors with sense wires are still in use today in small experiments as well as modern ones as those at the LHC. This short note is about the construction of a small wire chamber with limited resources, which could be used both as…

Instrumentation and Detectors · Physics 2014-09-02 Saime Gurbuz , Gokhan Unel , Samim Erhan

We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…

Instrumentation and Detectors · Physics 2018-10-17 Marco Cortesi , Yassid Ayyada , John Yurkon

In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout…

We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in…

The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The…

In this paper, we study the influence of the radius of a cylindrical supporting structure on radiation properties of a conformal millimeter-wave antenna array. Bent antenna array structures on cylindrical surfaces may have important…

Instrumentation and Detectors · Physics 2015-02-27 V. Semkin , A. Bisognin , M. Kyro , V-M. Kolmonen , C. Luxey , F. Ferrero , F. Devillers , A. V. Raisanen

We report on a recently developed novel type of large area (62 mm x 62 mm) position sensitive silicon detector with four-corner readout. It consists of a square-shaped ion-implanted resistive anode framed by additional low-resistivity…

Nuclear Experiment · Physics 2008-11-26 A. Banu , Y. Li , M. McCleskey , M. Bullough , S. Walsh , C. A. Gagliardi , L. Trache , R. E. Tribble , C. Wilburn

A one-coordinate gaseous detector of soft X-ray photons for wide-angle X-ray scattering (WAXS) studies is being developed. The detector operates in counting mode and is based on multi-stage Gas Electron Multiplier(GEM). Full size detector…

Instrumentation and Detectors · Physics 2008-11-26 V. M. Aulchenko , P. A. Papushev , M. R. Sharafutdinov , L. I. Shekhtman , V. M. Titov , B. P. Tolochko , V. V. Zhulanov

Gas leakage is a serious hazard in a variety of sectors, including industrial, domestic, and gas-powered vehicles. The installation of gas leak detection systems has emerged as a critical preventative measure to solve this problem.…

Signal Processing · Electrical Eng. & Systems 2023-07-06 Ayush Singh , Harikrishnan Pisharody Gopalkrishnan , Mahesh Raveendranatha Panicker

A position sensitive thin gap chamber has been developed. The position resolution was measured using the cosmic muons. This paper presents the structure of this detector, position resolution measurement method and results.

Instrumentation and Detectors · Physics 2015-06-17 Yanyan Du , Tongye Xu , Ruobin Shao , Xu Wang , Chengguang Zhu

A new Micromegas manufacturing technique, based on kapton etching technology, has been recently developed, improving the uniformity and stability of this kind of readouts. Excellent energy resolutions have been obtained, reaching 11% FWHM…

Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the…

Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this…

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

Instrumentation and Detectors · Physics 2020-01-29 A. Rocchi , R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento

Different types of ground-based detectors have been developed and deployed around the world to monitor and study CR variations. We have designed, constructed and operated a three layer small (20x20 cm2) multiwire proportional chamber MWPC…

Instrumentation and Detectors · Physics 2016-01-01 Abdullrahnan Maghrabi , Mohammed Al Enizy , A Aldosari , M Almuteri

In this study we investigate the stability limits of Micromegas detectors upon irradiation with alpha particles. The results are obtained with meshes with different optical transparency and geometry of wires. The measurements are performed…

Instrumentation and Detectors · Physics 2023-06-13 P. Gasik , T. Waldmann , L. Fabbietti , T. Klemenz , L. Lautner , B. Ulukutlu

The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche…

We present the first micropattern gaseous detector that employs a small 3D-printed Thick-GEM as its sole gain element. The detector can achieve sufficient gas gain for regular operation without the need for pre-amplification by additional…

Instrumentation and Detectors · Physics 2025-11-11 J. Collins , M. Hohlmann

NEWAGE(NEw generation WIMP search with an Advanced Gaseous tracking device Experiment) project is a direction-sensitive dark matter search experiment with a gaseous micro time-projection-chamber(micro-TPC). We report on the performance of…

We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche…

Instrumentation and Detectors · Physics 2015-06-26 C. Iacobaeus , T. Francke , B. Lund-Jensen , J. Ostling , P. Pavlopoulos , V. Peskov , F. Tokanai