Related papers: The NA48 Liquid Krypton Calorimeter Description an…
We present the results of a test beam campaign on a capillary-tube fibre-based dual-readout calorimeter, designed for precise hadronic and electromagnetic energy measurements in future collider experiments. The calorimeter prototype…
The R&D project COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) aims to develop a cryogenic scintillating calorimeter using NaI as target crystal for direct darkmatter search. Dark matter…
In kaon physics, several new precision measurements on flavour variables and CP violation have performed in the recent years. Presented are a new precise determination of the CKM parameter |V_us|, which combines the results of all…
Liquid scintillator detectors are playing an increasingly important role in low-energy neutrino experiments. In this article, we describe a generic energy response model of liquid scintillator detectors that provides energy estimations of…
We study the response of a prototype Zero-Degree Calorimeter (ZDC) detector to irradiation equivalent to 10$^{11}$ 1-MeV $n_{\text{eq}}/\text{cm}^{2}$, which matches the expected exposure after one year of operation at full nominal…
We present a new publicly available dataset that contains simulated data of a novel calorimeter to be installed at the CERN Large Hadron Collider. This detector will have more than six-million channels with each channel capable of position,…
Detailed Monte-Carlo simulations were used to evaluate the performance of a liquid neon scintillation detector for dark matter and low-energy solar neutrino interactions. A maximum-likelihood event vertex fitter including PMT time…
We review different definitions of the $\epsilon'$ parameter describing direct CP violation in neutral kaon decays, which was precisely measured in recent experiments, and point out the inconsistency of some of them due to a CPT constraint.…
A commercially available calorimeter has been used to investigate the specific heat of a high-quality \kn\ single crystal. The addenda heat capacity of the calorimeter is determined in the temperature range $0.02 \, \mathrm{K} \leq T \leq…
A high performance distillation system to remove krypton from xenon was constructed, and a purity level of Kr/Xe = $\sim 3 \times 10^{-12}$ was achieved. This development is crucial in facilitating high sensitivity low background…
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is…
In this study, we developed a new proton detector system called CATCH, which was designed for a scattering experiment involving a $\Sigma$ hyperon and a proton (J-PARC E40). CATCH is a cylindrical detector system covering an inner target…
Sufficient energy resolution is the key issue for the calorimetry in particle and nuclear physics. The calorimeter of the A4 parity violation experiment at MAMI is a segmented calorimeter where the energy of an event is determined by…
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…
$^{83m}Kr$ and $^{22}Na$ have been used in calibrating a liquid argon (LAr) detector.$^{83m}Kr$ atoms are produced through the decay of $^{83}Rb$ and introduced into the LAr detector through the circulating purification system. The light…
This paper describes results on R&D of an economical and efficient cryogenic system prototype for future liquid xenon detector. The test module of the prototype has a "cold head" attached to a copper rod, which is specially designed to…
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…
The RD52 Project at CERN is a pure instrumentation experiment whose goal is to understand the fundamental limitations to hadronic energy resolution, and other aspects of energy measurement, in high energy calorimeters. We have found that…
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$ scintillation…
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid…