English
Related papers

Related papers: Development of a Large-Area Aerogel Cherenkov Coun…

200 papers

To identify $\pi^{\pm}$ and $K^{\pm}$ in the region of $1.0\sim 2.5$ GeV/c, a threshold Cherenkov counter equipped with silica aerogels has been investigated. Silica aerogels with a low refractive index of 1.013 have been successfully…

High Energy Physics - Experiment · Physics 2009-10-22 I. Adachi et al

We describe a new aerogel threshold Cherenkov detector installed in the HMS spectrometer in Hall C at Jefferson Lab. The Hall C experimental program in 2003 required an improved particle identification system for better identification of…

Instrumentation and Detectors · Physics 2009-11-10 R. Asaturyan , R. Ent , H. Fenker , D. Gaskell , G. M. Huber , M. Jones , D. Mack , H. Mkrtchyan , B. Metzger , N. Novikoff , V. Tadevosyan , W. Vulcan , S. Wood

We have designed a threshold Cherenkov detector at the Rutherford-Appleton Laboratory to identify muons with momenta between 230 and 350 MeV/c. We investigated the properties of three aerogels for the design. The nominal indexes of…

Instrumentation and Detectors · Physics 2009-09-28 Lucien Cremaldi , David A. Sanders , Peter Sonnek , Donald J. Summers , Jim Reidy

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle…

New highly transparent, hydrophobic silica aerogels with refractive indices of 1.01 to 1.07 have been produced by Aspen Aerogels, Inc., and select tiles have been tested using an electron beam at the DESY, Hamburg facility. A…

Instrumentation and Detectors · Physics 2018-01-15 D. Blyth , R. Alarcon , R. Begag , J. Holmes , J. Stryker

This study presents the development of hydrophobic silica aerogel for use as a radiator in threshold-type Cherenkov counters. These counters are to be used for separating positrons and positive muons produced by kaon decay in the J-PARC…

Instrumentation and Detectors · Physics 2015-06-22 Makoto Tabata , Akihisa Toyoda , Hideyuki Kawai , Youichi Igarashi , Jun Imazato , Suguru Shimizu , Hirohito Yamazaki

Silica aerogels are important to be used as photon radiators in Cherenkov counters for high-energy-physics experiments because of their optical transparency and intermediate refractive indices between those of gases and liquids or solids.…

Instrumentation and Detectors · Physics 2023-10-10 Makoto Tabata

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with…

A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel…

We have succeeded in developing hydrophobic silica aerogels over a wide range of densities (i.e. refractive indices). A pinhole drying method was invented to make possible producing highly transparent aerogels with entirely new region of…

Instrumentation and Detectors · Physics 2011-12-22 Makoto Tabata , Ichiro Adachi , Yoshikazu Ishii , Hideyuki Kawai , Takayuki Sumiyoshi , Hiroshi Yokogawa

The Alpha Magnetic Spectrometer in a precursor version (AMS-01), was flown in June 1998 on a 51.6 degrees orbit and at altitudes ranging between 320 and 390 km, on board of the space shuttle Discovery (flight STS-91). AMS-01 included an…

This study presents the development of large-area (18 $\times $ 18 $\times $ 2 cm$^3$), high refractive index ($n \sim $1.05) hydrophobic silica aerogel tiles for use as Cherenkov radiators. These transparent aerogel tiles will be installed…

Instrumentation and Detectors · Physics 2017-01-03 Makoto Tabata , Ichiro Adachi , Yoshikiyo Hatakeyama , Hideyuki Kawai , Takeshi Morita , Takayuki Sumiyoshi

This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward…

We report on a design and performances of a monitoring system developed for the aerogel Cherenkov counters (ACC) of the BELLE detector. The system consists of blue LEDs, a diffuser box, and optical distributors which distribute the LED…

High Energy Physics - Experiment · Physics 2014-11-17 M. H. R. Khan , A. Murakami , T. Sumiyoshi , T. Kuniya , I. Adachi , R. Enomoto , H. Hattori , T. Iijima , K. Kaneda , R. Kawabata , T. Ooba , R. Suda , K. Suzuki , M. Watanabe

This thesis discusses two different approaches for the measurement of cosmic-ray antiparticles in the GeV to TeV energy range. The first part of this thesis discusses the prospects of antiparticle flux measurements with the proposed PEBS…

Instrumentation and Methods for Astrophysics · Physics 2009-09-15 Ph. von Doetinchem

We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result…

Instrumentation and Detectors · Physics 2016-06-21 Y. Maeda , N. Kawasaki , T. Masuda , H. Morii , D. Naito , Y. Nakajima , H. Nanjo , T. Nomura , N. Sasao , S. Seki , K. Shiomi , T. Sumida , Y. Tajima

The work is devoted to the development of the aerogel Cherenkov counters with the light collection on wavelength shifters and PMTs (ASHIPH). The ASHIPH system has been developed for the KEDR detector. Tests of the counters have been carried…

Micromegas is presently in use by many experiments providing enhanced performance when used in high particle environment. Compared with other solid-state detectors or conventional gas counters Micromegas is robust and radiation hard. Recent…

Instrumentation and Detectors · Physics 2008-11-26 I. Giomataris

We report recent progress in the development of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter to be installed in the forward end cap of the Belle II detector, which…

Instrumentation and Detectors · Physics 2014-11-18 Makoto Tabata , Ichiro Adachi , Hideyuki Kawai , Shohei Nishida , Takayuki Sumiyoshi

The Alpha Magnetic Spectrometer (AMS) was flown in june 1998 on board of the space shuttle Discovery (flight STS-91) at an altitude ranging between 320 and 390 km. This preliminary version of AMS included an Aerogel Threshold Cherenkov…

Astrophysics · Physics 2007-05-23 F. Mayet
‹ Prev 1 2 3 10 Next ›