Related papers: The Forward Proton Detector at D0
An overview of the present activities and long-term R&D plans of the Spanish network for future linear accelerators aiming to design and construct the Forward Tracker Detector (FTD) system of ILD, is shown
The ZEUS detector at HERA has been supplemented with a presampler detector in front of the forward and rear calorimeters. It consists of a segmented scintillator array read out with wavelength-shifting fibers. We discuss its desi gn,…
We are on the way to obtaining multi-dimensional "pictures" of the proton. The field is bursting with activities, both from the theoretical and experimental side. A brief selection of important achievements of the last years and open…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
Performances of the Very Forward Proton Spectrometer (VFPS) of the H1 detector at HERA using data collected during the 2006/2007 running period are discussed, including the description of acceptance, reconstruction of proton energy loss and…
ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation…
The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…
The forward physics program of the CMS experiment at the LHC spans a broad range of diverse physics topics including studies of low-x QCD and diffractive scattering, multi-parton interactions and underlying event structure, gamma-mediated…
We present recent results from the Collider Detector at Fermilab (CDF) and D0 experiments using data from proton-antiproton collisions with sqrt(s) = 1.96 TeV at Run II of the Fermilab Tevatron. New physics may appear in events with high…
We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters…
In the present paper, we report on our developments of liquid xenon detectors for medical imaging, positron emission tomography and single photon imaging, in particular. The results of the studies of several photon detectors…
We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects…
This work reports on the development of the first phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for the CRESST-II experiment. In particular, a novel technique for the production of the ZnWO4 phonon detector with a…
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different…
The project involved the development of a precision radioactive Source-Positioning System to enable the absolute characterization of a gamma-ray Detector-Development Platform at the Division of Nuclear Physics at Lund University in…
We present a novel approach to the readout of ionization detectors. The solution allows to minimize the number of components and the space occupation close to the detector. This way a minimal impact is added on the radioactive background in…
This paper describes the design, fabrication, installation and performance of the new inner layer called Layer 0 (L0) that was inserted in the existing Run IIa Silicon Micro-Strip Tracker (SMT) of the D0 experiment at the Fermilab Tevatron…
This paper describes a novel directional neutron detector prototype. The low pressure time projection chamber uses a mix of helium and CF4 gases. The detector reconstructs the energy and angular distribution of fast neutron recoils. This…
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype…
The relative merits and disadvantages of various alternatives for vertexing and central tracking detectors for the Linear Collider detector are presented. Research and development prospects for the various alternatives are also discussed,…