Related papers: Scintillation Counters for the D0 Muon Upgrade
The general strategy, as well as channel-specific details, applied to the measurement of the top quark mass at the Tevatron in Run I are reviewed, and the combination of the results obtained by the CDF and DO collaborations presented. The…
Over the course of the past years the experimental measurements performed by the two large collaborations, CDF and D{\O}, at the Fermilab Tevatron Collider have fueled advances in our understanding of physics at the energy frontier. At the…
Noise characteristics and MIP registration efficiency of the Scintillation Tile with MRS APD Light Readout (START) were measured with cosmic particles. Encouraging results open a broad range of possibilities for using START in large-scale…
We review the diffractive measurements made by the CDF and D\O\ collaborations during Run I at the Tevatron and summarize the detector upgrades relevant for the Run II diffractive physics program.
The CMS muon system is undergoing substantial upgrades to meet the challenges of the High-Luminosity LHC (HL-LHC), including the installation of the new Muon Endcap 0 (ME0) detector. Large-scale production started in 2024. ME0 is a…
We present a combination of measurements of the top quark mass by the D0 experiment in the lepton+jets and dilepton channels. We use all the data collected in Run I (1992--1996) at $\sqrt s=1.8$ TeV and Run II (2001--2011) at $\sqrt s=1.96$…
The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the…
The Tevatron Run-II program has been in progress since 2001, and the CDF and D0 experiments have been operational with upgraded detectors. Coupled with recent improvements in the Tevatron accelerator performance, the experiments have…
The MicroBooNE experiment is a liquid argon TPC experiment designed for short-baseline neutrino physics, currently running at Fermilab. Due to its location near the surface, cosmic muons can be a source of backgrounds to many analyses and…
The possibility to build a SiPM-readout muon detector (SiRO), using plastic scintillators with optical fibers as sensitive volume and readout by SiPM photo-diodes, is investigated. SiRO shall be used for tracking cosmic muons based on…
Muons have a similar latency/energy correlation from pion decay as do the neutrinos, and hence in each time-slice in a stroboscopic analysis measurements of their momentum spectra can reduce systematic uncertainties due to flux. There are,…
Muon Colliders have unique technical and physics advantages and disadvantages when compared with both hadron and electron machines. They should thus be regarded as complementary. Parameters are given of 4 TeV and 0.5 TeV high luminosity…
Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field…
We present recent results on Technicolor and Leptoquark searches obtained analyzing up to 0.4 fb-1 of data taken at Fermilab by the D0 experiment during the firs part of the Tevatron Run II.
Experiments such as mu2e (FNAL, USA) and COMET (KEK, Japan), seeking the direct muon-to-electron conversion as part of the study of Charged Leptons Flavor Violation processes, should have a extremely high, up-to 99.99\%, efficiency muon…
Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per…
The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative…
Since the end of Run 1 of the LHC in 2012, the outermost ring has been added to the CMS Cathode Strip Chambers (CSC) endcap muon detector, and the readout electronics of the innermost ring of CSCs have been upgraded to accommodate the…
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground…
The Tevatron's record luminosities enable a program systematically addressing the physics of the top quark. The CDF and D0 experiments are pioneering measurements across the full breadth of topics. Some of their most recent results are…