Related papers: Time Resolution and Linearity Measurements for a S…
Visible light photon counters (VLPCs) offer many attractive features as photon detectors, such as high quantum efficiency and photon number resolution. We report measurements of the single-photon timing jitter in a VLPC, a critical…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…
The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…
The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained…
In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…
We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…
Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…
Photon number resolving detectors are needed for a variety of applications including linear-optics quantum computing. Here we describe the use of time-multiplexing techniques that allows ordinary single photon detectors, such as silicon…
The light yield and the time resolution of different types of 3 m long scintillating bars instrumented with wavelength shifting fibres and read out by different models of silicon photomultipliers have been measured at a test beam at the T9…
Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism of resistive plate chambers (RPCs) are expected to have both a large photocoverage and an excellent time resolution and to be low-cost. To demonstrate the…
One contribution to the time resolution of a scintillation detector is the signal time spread due to path length variations of the detected photons from a point source. In an experimental study a rectangular scintillator was excited by…
Time-resolved photoconductivity is widely used to characterize non-equilibrium charge-carrier lifetime, impurity content, and solar cell efficiency in a broad range of semiconductors. Most measurements are limited to the detection of…
Energy nonlinearity and resolution in liquid scintillator (LS) detectors are correlated and particle-dependent. A unified energy response model for liquid scintillator detectors has been presented in details. This model has advanced a…
Liquid xenon (LXe) is a well-studied detector medium to search for rare events in dark matter and neutrino physics. Two-phase xenon time projection chambers (TPCs) can detect electronic and nuclear recoils with energy down to kilo-electron…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…
A gaseous time-projection chamber (TPC) with a reconstructable $z$ coordinate for nuclear recoil tracks has been developed for dark-matter searches and $\alpha$ particle imagings in a low radioactivity background. A TPC with a…