English
Related papers

Related papers: A Compact Gas Cerenkov Detector with Novel Optics

200 papers

The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH$_4$ and TEA gases. The first two photon detector modules which were…

A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel…

A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam…

We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes.…

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle…

A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index…

To identify $\pi^{\pm}$ and $K^{\pm}$ in the region of $1.0\sim 2.5$ GeV/c, a threshold Cherenkov counter equipped with silica aerogels has been investigated. Silica aerogels with a low refractive index of 1.013 have been successfully…

High Energy Physics - Experiment · Physics 2009-10-22 I. Adachi et al

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must…

Instrumentation and Detectors · Physics 2016-06-28 M. Blatnik , K. Dehmelt , A. Deshpande , D. Dixit , N. Feege , T. K. Hemmick , B. Lewis , M. L. Purschke , W. Roh , F. Torales-Acosta , T. Videbaek , S. Zajac

Cherenkov threshold detectors (XCET) are used for identifying particles in the experimental areas at CERN. These detectors observe Cherenkov light emitted by charged particles travelling inside a pressurized gas vessel. A key component of…

We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result…

Instrumentation and Detectors · Physics 2016-06-21 Y. Maeda , N. Kawasaki , T. Masuda , H. Morii , D. Naito , Y. Nakajima , H. Nanjo , T. Nomura , N. Sasao , S. Seki , K. Shiomi , T. Sumida , Y. Tajima

The CLEO detector will undergo major improvements in conjunction with a high luminosity upgrade of the CESR electron positron collider, that should increase the luminosity of this machine by a factor of 10. The most innovative feature of…

High Energy Physics - Experiment · Physics 2008-11-26 Marina Artuso

The construction and use of a dual radiator Ring Imaging Cerenkov(RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasizes measurements of semi-inclusive deep-inelastic scattering. It…

Instrumentation and Detectors · Physics 2009-09-25 N. Akopov

We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the…

Cosmic ray muons present a large part of the radiation background and depending on the application of interest muons can be seen as background noise, e.g., radiation mapping, radiation protection, dosimetry, or as a useful interrogation…

Instrumentation and Detectors · Physics 2022-01-10 Junghyun Bae , Stylianos Chatzidakis

A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…

A Ring Imaging \v{C}erenkov detector built for the BRAHMS experiment at the Brookhaven RHIC is described. This detector has a high index of refraction gas radiator. \v{C}erenkov light is focused on a photo-multiplier based photon detector…

Instrumentation and Detectors · Physics 2008-11-26 R. Debbe , C. E. Jorgensen , J. Olness , Z. Yin

A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the…

Instrumentation and Detectors · Physics 2015-12-18 Craig Woody , Babak Azmoun , Richard Majka , Michael Phipps , Martin Purschke , Nikolai Smirnov

CLEO III upgrade was completed with the integration of Ring Imaging CHerenkov(RICH) detector for charged particle identification. The design of this cylindrical detector consists of LiF crystal radiators and multi-wire proportional chamber…

High Energy Physics - Phenomenology · Physics 2009-10-31 Gobinda Majumder

We report on the design, construction, commissioning, and performance of a threshold gas \v{C}erenkov counter in an open configuration, which operates in a high luminosity environment and produces a high photo-electron yield. Part of a…

Instrumentation and Detectors · Physics 2015-12-09 Whitney R. Armstrong , Seonho Choi , Ed Kaczanowicz , Alexander Lukhanin , Zein-Eddine Meziani , Brad Sawatzky

The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout…