Related papers: GaAs Microstrip Testbeam Results
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…
A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…
We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a…
A novel graphene-optimized silicon carbide PIN detector was fabricated. Its electrical properties, charge collection performance and signal rise time were evaluated under non-irradiated conditions and under X-ray irradiation with an energy…
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…
Gallium solar neutrino experiments have historically used radiochemical counting to determine the event rate. A detector which directly measures the ejected electron and de-excitation gamma could reduce background counting rates by way of a…
We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas…
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
We design a GeV gamma ray detector based on an electron-positron pair measurement by using the BESS-polar magnet and study it with the GEANT4 simulation code. We consider an additional counter to select an electron-positron pair for which…
Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…
We present the results of the operation of an array of avalanche photodiodes (APDs) for the readout of an electroluminescence detector. The detector contains 24 APDs with a pitch of 15 mm between them allowing energy and position…
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of…
Continuous-wave squeezed states of light at the wavelength of 1550 nm have recently been demonstrated, but so far the obtained factors of noise suppression still lag behind today's best squeezing values demonstrated at 1064 nm. Here we…
For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High…
The next upgrade of the GEO600 gravitational wave detector is scheduled for 2010 and will, in particular, involve the implementation of squeezed light. The required non-classical light source is assembled on a 1.5m^2 breadboard and includes…
Gas Electron Multiplier (GEM) detectors, typically featuring a standard pitch size of 140 $\mu$m and an inner hole diameter of 50 $\mu$m, are extensively utilized in high-energy physics experiments for tracking, triggering, and timing…