Related papers: W Mass and Properties
The measurements performed at LEP and SLC have substantially improved the precision of the test of the Minimal Standard Model. The precision is such that there is sensitivity to pure weak radiative corrections. This allows to indirectly…
We explore the ability of the Large Hadron Collider to measure the mass of the W boson. We believe that a precision better than 15 MeV could be attained, based on a year of operation at low luminosity (10^{33} cm^-2 s^-1). If this is true,…
We present a measurement of the W boson mass using data collected with the CDF detector during the 1994-95 collider run at the Fermilab Tevatron. A fit to the transverse mass spectrum of a sample of 30,115 W -> enu events recorded in an…
Precise measurements of the mass and width of the W boson are carried out in e+e- collisions at LEP, by kinematic reconstruction of the invariant mass distributions of WW->qqlv and WW->qqqq candidate events. The most recent combination of…
The mass and width of the W boson are measured using e+e- -> W+W- events from the data sample collected by the OPAL experiment at LEP at centre-of-mass energies between 170 GeV and 209 GeV. The mass (mw) and width (gw) are determined using…
We present a measurement of the W boson mass using 200/pb of data collected in pbar p collisions at sqrt(s) = 1.96 TeV by the CDF II detector at Run II of the Fermilab Tevatron. With a sample of 63964 W -> e nu candidates and 51128 W -> mu…
We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF…
We describe a measurement of the W boson mass mW using 200/pb of root-s = 1.96 TeV p-pbar collision data taken with the CDF II detector. With a sample of 63,964 W -> e nu candidates and 51,128 W -> mu nu candidates, we measure mW = [80.413…
We present a new measurement of the $W$ mass using the $W\to e\nu$ data from the D\O forward detectors at the Fermilab Tevatron $p \bar p$ Collider. This is the first measurement of the $W$ mass with electron candidates in the range $1.5 <…
The CDF II detector at the Tevatron collider reported significant tension between the measurement of the W boson mass and the Standard Model prediction, assuming that 125 GeV scalar discovered at the LHC is the Higgs boson. We calculate one…
We present a measurement of the $W$-boson mass, $M_W$, using data corresponding to 2.2/fb of integrated luminosity collected in ppbar collisions at $\sqrt{s}$ = 1.96 TeV with the CDF II detector at the Fermilab Tevatron. The selected sample…
We report a selection of the most recent CDF and D0 results on top quark and W and Z boson properties, based on Tevatron Run 2 data. The large datasets of W and Z bosons allow a very precise measurement of the W mass and detailed studies of…
Most recent results of $W$ boson mass and width measurements performed by CDF and D are reported. at the center-of-mass energy of 1.96 TeV. Integrated luminosity ranges from 0.2 fb$^{-1}$ to 1.0 fb$^{-1}$ depending on the analysis.
We present an update of the Standard Model fit to electroweak precision data. We include newest experimental results on the top quark mass, the W mass and width, and the Higgs boson mass bounds from LEP, Tevatron and the LHC. We also…
We present a measurement of the W boson mass in W -> ev decays using 1 fb^-1 of data collected with the D0 detector during Run II of the Fermilab Tevatron collider. With a sample of 499830 W -> ev candidate events, we measure M_W = 80.401…
The Standard Model of electroweak interactions has had great success in describing the observed data over the last three decades. The precision of experimental measurements affords tests of the Standard Model at the quantum loop level…
We have measured the W-boson mass MW using data corresponding to 2.2/fb of integrated luminosity collected in proton-antiproton collisions at 1.96 TeV with the CDF II detector at the Fermilab Tevatron collider. Samples consisting of 470126…
I describe the latest D0 and CDF W boson mass measurements. The D0 measurement is performed with $4.3\, fb^{-1}$ of integrated luminosity in the electron decay channel with a data set of $1.68\times 10^{6}$ W candidates. The value of the W…
We report a measurement of the W boson mass based on an integrated luminosity of 82/pb from p-pbar collisions at sqrt(s) = 1.8 TeV recorded in 1994-1995 by the D0 detector at the Fermilab Tevatron. We identify W bosons by their decays to…
The potential of a linear e+e- collider operated at a centre-of-mass energy of 350 GeV is studied for the measurement of the Higgs boson mass. An integrated luminosity of 500 fb-1 is assumed. For Higgs boson masses of 120, 150 and 180 GeV…