Related papers: Muon g-2
The muon anomalous magnetic moment, $a_\mu = (g-2)/2$, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics.…
We present the final report from a series of precision measurements of the muon anomalous magnetic moment, a_mu = (g-2)/2. The details of the experimental method, apparatus, data taking, and analysis are summarized. Data obtained at…
The New Muon $(g-2)$ Collaboration at Fermilab has proposed to measure the anomalous magnetic moment of the muon, $a_\mu$, a factor of four better than was done in E821 at the Brookhaven AGS, which obtained $a_\mu = [116 592 089 (63)]…
The anomalous magnetic moment of the muon has been measured to 0.5 ppm in a series of precision experiments at the Brookhaven Alternating Gradient Synchrotron. The individual results for each sign: a(mu+)= 11 659 204(7)(5) E-10 and a(mu-) =…
The muon (g-2) experiment at Brookhaven National Laboratory has measured the anomalous magnetic moment of the positive muon with a precision of 0.7 ppm. This paper presents that result, concentrating on some of the important experimental…
We present a new, completely revised calculation of the muon anomalous magnetic moment, $a_\mu=(g_{\mu}-2)/2$, comparing it with the more recent experimental determination of this quantity; this furnishes an important test of theories of…
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_\mu \equiv (g_\mu-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of…
We present details on a new measurement of the muon magnetic anomaly, $a_\mu = (g_\mu -2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
The status of the muon (g-2) experiment at the Brookhaven AGS is reviewed. An accuracy of 1.3 ppm on the mu^+ anomalous magnetic moment has been achieved and published. This result differs with the standard model prediction by about 2.5…
Anomalous magnetic moment of the muon, $a_{\mu}=(g_{\mu}-2)/2$, is one of the most precisely measured quantities in particle physics and it provides a stringent test of the Standard Model. The planned improvements of the experimental…
The current $\sim3.5\sigma$ discrepancy between the experimental measurement and theoretical prediction of the muon magnetic anomaly, $a_{\mu}$, stands as a potential indication of the existence of new physics. The Muon $g-2$ experiment at…
The muon anomalous magnetic moment is one of the most precisely measured quantities in particle physics. Recent high precision measurements (0.54ppm) at Brookhaven reveal a ``discrepancy'' by 3 standard deviations from the electroweak…
The current status of the Standard Model prediction for the anomalous magnetic moment of the muon is briefly reviewed and compared with the present experimental value.
The calculations entering the prediction of the standard model value for the anomalous magnetic moment of the muon $a_\mu$ are reviewed, and compared to the very accurate experimental measurement. The situation for the electron is discussed…
The muon anomalous magnetic moment measurement, when compared with theory, can be used to test many extensions to the standard model. The most recent measurement made by the Brookhaven E821 Collaboration reduces the uncertainty on the world…
QED, Hadronic, and Electroweak Standard Model contributions to the muon anomalous magnetic moment, a_mu = (g_mu-2)/2, and their theoretical uncertainties are scrutinized. The status and implications of the recently reported 2.6 sigma…
A review of the theoretical and experimental values for the charged lepton (electron and muon) anomalous magnetic moment $a_l= (g_l-2)/2$ is presented. Employing the most accurate value for the fine structure constant $\alpha^{-1}=…
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment $a_{\mu}$ . This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation…
The measurement of the anomalous magnetic moment of the muon provides a stringent test of the standard model and of any physics that lies beyond it. There is currently a deviation of $3.1\sigma$ between the standard model prediction for the…