Related papers: A new ring structure for muon (g-2) measurements
A new experiment to measure the muon g-2 factor is proposed. We suppose the sensitivity of this experiment to be about 0.03 ppm. The developed experiment can be performed on an ordinary storage ring with a noncontinuous field created by…
The Muon $(g-2)$ experiment, E821, at the Brookhaven AGS has the goal to measure the muon anomalous magnetic moment to a relative accuracy of $\pm 3.5 \times 10^{-7}$. A superferric 14 m diameter storage ring has been constructed and an…
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018.…
A new superferric magnetic storage ring with highly homogeneous field at 1.45 T and weak electrostatic focussing is described which has been set up at the Brookhaven National Laboratory (BNL), USA, for a precision measurement of the…
We present details on a new measurement of the muon magnetic anomaly, $a_\mu = (g_\mu -2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$…
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_\mu \equiv (g_\mu-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of…
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140…
A new measurement of the positive muon's anomalous magnetic moment has been made at the Brookhaven Alternating Gradient Synchrotron using the direct injection of polarized muons into the superferric storage ring. The angular frequency…
The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab has a goal of measuring the muon anomaly ($a_\mu$) with unprecedented precision using positive muons. This measurement is motivated by the difference between the previous Brookhaven…
The muon (g-2) experiment at Brookhaven National Laboratory has measured the anomalous magnetic moment of the positive muon with a precision of 0.7 ppm. This paper presents that result, concentrating on some of the important experimental…
The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…
A precision measurement of the muon anomalous magnetic moment, $a_{\mu} = (g-2)/2$, was previously performed at BNL with a result of 2.2 - 2.7 standard deviations above the Standard Model (SM) theoretical calculations. The same experimental…
We consider different types of storage rings as precision probes of axion-mediated monopole-dipole forces. We show that current and planned experiments aiming to measure magnetic and electric dipole moments of protons, muons and electrons…
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_{\mu} = (g-2)/2$, and the muon electric dipole moment (EDM) $d_{\mu}$ at the J-PARC muon facility. The goal of our experiment is to measure $a_{\mu}$ and…
The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more…
The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was…
The Muon g-2/EDM Experiment at J-PARC will employ a novel way to measure the muon magnetic anomaly, a_mu = (g-2)_mu/2, by using a low-emittance beam of positive muons stored in a compact muon storage magnet. The experimental method includes…
The new g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment by a fourfold improvement in precision compared to the BNL experiment. Achieving this goal requires the delivery of highly polarized 3.094 GeV/c muons…
The muon g-2 experiment at Brookhaven National Laboratory measures the anomalous magnetic moment of the muon, $a_\mu$, very precisely. This measurement tests the Standard Model. The analysis for the data collected in 2000 (a $\mu^+$ run) is…