Related papers: Development of a time projection chamber with micr…
A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the…
This paper presents a novel method for low maintenance, low ambiguity in-situ drift velocity monitoring in large volume Time Projection Chambers (TPCs). The method was developed and deployed for the 40m^3 TPC tracker system of the…
A large volume time projection chamber (TPC) has been proposed as main tracking device for a detector at a future linear e+e- collider. Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…
The Time Projection Chamber (TPC) has been recognized as a potentially powerful detector for the search of WIMPs by measuring the directions of nuclear recoils, in which the most convincing signature of WIMPs, caused by the Earth's motion…
Several new experimental concepts in high-energy particle physics have been proposed in recent years. The physical goals include precisely measuring the properties of particles such as Higgs, Z and W, and even looking for signs of new…
For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…
The Micro Pixel Chamber (mu-PIC) using resistive electrodes has been developed and tested. The surface cathodes are made from resistive material, by which the electrical field is reduced when large current is flowed. Two-dimensional…
Background: The established GADGET detection system, designed for measuring weak, low-energy $\beta$-delayed proton decays, features a gaseous Proton Detector with MICROMEGAS readout for calorimetric particle detection, surrounded by a…
High precision experiments with muons and pions often require tracking charged particles with $O(100~\mu\mathrm{m})$ single-hit resolution, possibly with particle identification capabilities, down to very low momenta ($p \lesssim…
An eight chip InGrid module has been tested as readout of a prototype time projection chamber. The construction of the modules as well as first preliminary results are presented. The InGrids, a Micromegas like amplification structure with a…
The physical processes of charge collection and gas multiplication of a Micro Pixel Chamber (mu-PIC) were studied in detail using a three-dimensional simulation. The collection efficiencies of primary electrons and gas multiplication…
This paper presents the Forward Time Projection Chamber (FTPC) system of the NA61/SHINE experiment at the CERN SPS accelerator. This TPC system applies a novel tandem-TPC design to reduce the background originating from particle tracks not…
Development of readout electronics for Time Projection Chamber for a Linear Collider is ongoing under stringent requirements on high channel density, lowest possible power consumption and small material budget. In the studied TPC readout…
We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The…
We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3$\times$1$\times$1~m$^3$) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of…
In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time…
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…
We propose a new imaging gamma-ray detector in the MeV region. By measuring the directions and energies of not only a scattered gamma ray but also a recoil electron, the direction of an incident gamma ray would be essentially reconstructed…
Studies of micro time projection chambers using negative ion gas (NI$\mu$TPC) are conducted especially for direction-sensitive dark matter searches. A NI$\mu$TPC enables to measure the absolute position in the drift direction for…