English
Related papers

Related papers: The "miniskirt" counter array at CDF-II

200 papers

New scintillation counters have been designed and constructed for the CDF upgrade in order to complete the muon coverage of the central CDF detector, and to extend this coverage to larger pseudorapidity. A novel light collection technique…

Instrumentation and Detectors · Physics 2009-11-10 A. Artikov , J. Budagov , G. Bellettini

We describe the design, construction and performance of the upgraded DO muon system for Run II of the Fermilab Tevatron collider. Significant improvements have been made to the major subsystems of the DO muon detector: trigger scintillation…

Instrumentation and Detectors · Physics 2009-09-29 The D0 Muon Group , V. M. Abazov

We present the results of an upgrade to the D0 muon system. Scintillating counters have been added to the existing central D0 muon system to provide rejection for cosmic ray muons and out-of-time background, and to provide additional fast…

High Energy Physics - Experiment · Physics 2012-08-27 D0 Collaboration

The CDF Central Preshower and Crack Detector Upgrade consist of scintillator tiles with embedded wavelength-shifting fibers, clear-fiber optical cables, and multi-anode photomultiplier readout. A description of the detector design, test…

Instrumentation and Detectors · Physics 2007-06-28 A. Artikov

Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the (forward) pseudorapidity region of $3.6<|\eta|<5.2$ of the CDF detector, have been recently installed as part of the Run II CDF upgrade at…

High Energy Physics - Experiment · Physics 2008-11-26 Stefano Lami

A muon-flux measurement behind the beam dump of the J-PARC Hadron Experimental Facility was performed with a compact muon detector that can be inserted into a vertical observing hole with 81 mm in diameter which was dug underground. The…

Instrumentation and Detectors · Physics 2024-10-30 T. Matsumura , Y. Hirayama , G. Y. Lim , H. Nanjo , T. Nomura , K. Shiomi , H. Watanabe

Two Miniplug calorimeters, designed to measure the energy and lateral position of particles in the forward pseudorapidity region of 3.6<|\eta |<5.1, have been installed as part of the CDF upgraded detector for Run II at the Tevatron.…

Accelerator Physics · Physics 2010-04-22 Michele Gallinaro

Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the pseudorapidity region of 3.6<|eta|<5.1 of the CDF detector, have been installed as part of the Run II CDF upgrade at the Tevatron collider.…

Instrumentation and Detectors · Physics 2014-11-18 K. Goulianos , M. Gallinaro , K. Hatakeyama , S. Lami , C. Mesropian , K. Terashi

The performance of the D0 experiment forward muon scintillation counters system during Run II of the Tevatron from 2001 to 2011 is described. The system consists of 4214 scintillation counters in six layers. The long term stability of the…

Instrumentation and Detectors · Physics 2015-06-19 V. Bezzubov , D. Denisov , V. Evdokimov , V. Lipaev , A. Shchukin , I. Vasilyev

Since the end of Run 1 of the LHC in 2012, the outermost ring has been added to the CMS Cathode Strip Chambers (CSC) endcap muon detector, and the readout electronics of the innermost ring of CSCs have been upgraded to accommodate the…

Instrumentation and Detectors · Physics 2015-11-02 H. Wells Wulsin

Muography, traditionally recognized as a potent instrument for imaging the internal structure of gigantic objects, has initialized various interdisciplinary applications. As the financial and labor costs of muography detector development…

Instrumentation and Detectors · Physics 2025-10-14 Tao Yu , Yunsong Ning , Yi Yuan , Shihan Zhao , Songran Qi , Minchen Sun , Yuye Li , Zhirui Liu , Aiyu Bai , Hesheng Liu , Yibo Lin , Geng Tuo , Ting On Chan , Zhou Zhou , Yu Chen , Yu Chen , Jian Tang

The CDF Forward Detector upgrade project was designed to enhance the capabilities for diffractive physics at the Tevatron. It consists of a Roman Pot spectrometer to detect leading antiprotons, a set of counters near and around the…

High Energy Physics - Phenomenology · Physics 2019-08-14 Michele Gallinaro

This paper reports on the design and construction of a chamber for the muon identifier detector (MID) of the ALICE 3 upgrade project. The chamber consists of two sensitive layers separated by a 1 cm air gap. Each layer holds 24 scintillator…

A detector designed to measure early particle showers has been installed in front of the central CDF calorimeter at the Tevatron. This new preshower detector is based on scintillator tiles coupled to wavelength-shifting fibers read out by…

Instrumentation and Detectors · Physics 2014-11-18 Michele Gallinaro

The physics program at the Fermilab Tevatron Collider will continue to explore the high energy frontier of particle physics until the commissioning of the LHC at CERN. The luminosity increase provided by the Main Injector will require…

Instrumentation and Detectors · Physics 2008-11-26 S. Kuhlmann , H. Frisch , M. Cordelli , J. Huston , R. Miller , S. Lami , R. Paoletti , N. Turini , M. Iori , D. Toback , T. Ukegawa

Small-diameter Muon Drift Tube (sMDT) chambers have been developed for the ATLAS muon detector upgrade. They possess an improved rate capability and a more compact design with respect to the existing chambers, which allows to equip detector…

Instrumentation and Detectors · Physics 2016-11-17 H. Kroha , O. Kortner , F. Müller , S. Nowak , K. Schmidt-Sommerfeld

The front face of the CDF central calorimeter is being equipped with a new Preshower detector, based on scintillator tiles read out by WLS fibers, in order to cope with the luminosity increase provided by the Main Injector during the…

Instrumentation and Detectors · Physics 2009-11-10 Stefano Lami

The Monitored Drift Tubes, as a part of the ATLAS muon spectrometer, are precision drift chambers designed to provide excellent spatial resolution and high tracking efficiency independent of the track angle. Through the life of the LHC and…

Instrumentation and Detectors · Physics 2021-12-15 G. H. Eberwein , O. Kortner , H. Kroha , M. Rendel , P. Rieck , D. Soyk , E. Voevodina , V. Walbrecht

The D0 detector at The Fermilab Tevatron is undergoing a major upgrade to prepare for data taking with luminosities reaching 2 x 10^{32} cm^{-2} s^{-1}. The upgrade includes a new central tracking array, new muon detector components and…

High Energy Physics - Experiment · Physics 2007-05-23 P. Petroff
‹ Prev 1 2 3 10 Next ›