Related papers: Recent Progress on the BNL Muon g-2 Experiment
The muon g-2 experiment at Brookhaven has been taking data since 1997. Analyses of the data taken in 1997 and 1998, which include about 2% of the data taken so far, have improved the experimental accuracy in the muon anomalous magnetic…
The Muon (g-2) Experiment (E821) at Brookhaven National Laboratory (BNL) has measured the anomalous magnetic moment of the positive muon to an unprecedented precision of 1.3 parts per million. The result, a_{\mu^+} = (g-2)/2 = 11 659…
The magnetic moment anomaly a_mu = (g_mu - 2) / 2 of the positive muon has been measured at the Brookhaven Alternating Gradient Synchrotron with an uncertainty of 0.7 ppm. The new result, based on data taken in 2000, agrees well with…
The muon (g-2) experiment at BNL has completed four data runs for the positive muon, beginning in 1997 and has just finished its first run for the negative muon. Recently the analysis of a 1.3 ppm result based on the 1999 run was completed…
The anomalous magnetic moment (g-2) of the muon was measured with a precision of 0.54 ppm in Experiment 821 at Brookhaven National Laboratory. A difference of 3.2 standard deviations between this experimental value and the prediction of the…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
The muon g-2 experiment at Brookhaven National Laboratory measures the anomalous magnetic moment of the muon, $a_\mu$, very precisely. This measurement tests the Standard Model. The analysis for the data collected in 2000 (a $\mu^+$ run) is…
A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…
The muon (g-2) experiment at Brookhaven National Laboratory has measured the anomalous magnetic moment of the positive muon with a precision of 0.7 ppm. This paper presents that result, concentrating on some of the important experimental…
The muon anomalous magnetic moment is one of the most precisely measured quantities in particle physics. In a recent experiment at Brookhaven it has been measured with a remarkable 14-fold improvement of the previous CERN experiment…
The E821 experiment at Brookhaven National Laboratory is designed to measure the muon magnetic anomaly, a_mu, to an ultimate precision of 0.4 parts per million (ppm). Because theory can predict a_mu to 0.6 ppm, and ongoing efforts aim to…
The Muon g-2 collaboration has measured the anomalous magnetic g value, a = (g-2)/2, of the positive muon with an unprecedented uncertainty of 0.7 parts per million. The result, based on data collected in the year 2000 at Brookhaven…
The precise measurement of the muon anomalous magnetic moment $a_\mathrm{\mu}$ has stimulated much theoretical and experimental efforts over more than six decades. The last experiment at Brookhaven National Laboratory, Upton, NY, USA…
The upcoming muon (g-2) experiment at Fermilab will measure the anomalous magnetic moment of the muon to a relative precision of 140 ppb, 4 times better than the previous experiment at BNL. The new experiment is motivated by the persistent…
We present the final report from a series of precision measurements of the muon anomalous magnetic moment, a_mu = (g-2)/2. The details of the experimental method, apparatus, data taking, and analysis are summarized. Data obtained at…
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released…
The muon anomalous magnetic moment, $a_\mu = (g-2)/2$, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics.…
The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The Muon g-2 experiment at Fermilab seeks to measure the muon magnetic moment anomaly, $a_\mu =(g-2)/2$, with a final target precision of 0.14 parts-per-million (ppm). The experiment's initial result, published in 2021 using Run 1 data from…
The Fermilab Muon $g-2$ experiment measures the muon anomalous magnetic moment with high precision. Together with recent improvements on the theory front, the first results of the experiment confirm the long-standing discrepancy between the…