Related papers: A first Design of the Pep-N Calorimeter
A very preliminary study for a trigger for the PEP-N experiment is presented. Its aim is to show the feasibility of a very efficient trigger for multihadronic events based on energy releases in the electromagnetic calorimeter. Though the…
Chromatic calorimetry introduces a novel approach to calorimeter design in High Energy Physics (HEP) by integrating Quantum Dot (QD) technology into traditional homogeneous calorimeters. The tunable emission spectra of QDs provide new…
This document is devoted to the electromagnetic calorimeter of the Forward Spectrometer and describes the design considerations, the technical layout, the expected performance, and the production readiness.
We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy…
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The…
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…
The angular coverage extension of the KLOE-2 electromagnetic calorimeter, from a polar angle of 20$^{\circ}$ down to $8^{\circ}$, will increase the multiphoton detection capability of the experiment enhancing the search reach for rare kaon,…
The CALICE prototype for a Si/W electromagnetic calorimeter has been tested in large scale test beams. Several million events with electrons and hadrons of different energies and impact angles have been recorded. The energy resolution has…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton…
This paper presents mechanical R&D for the CALICE Silicon-tungsten electromagnetic calorimeter. After the physics ECAL prototype, tested in 2006 (DESY-CERN), 2007 (CERN), 2008 (FNAL) and before the design of different "modules 0" (barrel…
The spatial resolution of laterally segmented electromagnetic calorimeters is studied on the basis of Monte-Carlo simulations worked-out for lead fluoride material. Parametrization of the relative resolution is proposed and optimized in…
The method of extraction of the e/h ratio for an electromagnetic compartment of a combined calorimeter is suggested and the non-compensation was determined. The results agree with the Monte Carlo prediction and results of the weighting…
In order to extend the direct observation of high-energy cosmic rays up to the PeV region, highly performing calorimeters with large geometrical acceptance and high energy resolution are required. Within the constraint of the total mass of…
The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number…
We discuss the design of an optical system that allows measurement of 600 nm to 1650 nm emission spectra for individual nanoparticles (NPs), laser heated in an electrodynamic trap in controlled atmospheres. An approach to calibration of…
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…
The status of the prototype readout boards for the CALICE electromagnetic calorimeter is presented. Results on linearity, noise, and minimum ionising signals, both from a radiactive source and cosmic rays, are shown.
Future HEP experiments present stringent challenges to calorimeter materials in radiation tolerance, time response and project cost. The 2019 report of the DOE Basic Research Needs Study on High Energy Physics Detector Research and…
The MUonE experiment proposes a novel approach to determine the leading hadronic contribution to the muon g-2, from a precise measurement of the differential cross section of the $\mu-e$ elastic scattering, achievable by using the CERN SPS…