Related papers: CMD-2 Detector Upgrade
The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise…
The CLEO detector at the Cornell Electron Storage Ring (CESR) is completing a major upgrade that significantly extends its physics reach in the study of heavy quarks and leptons. The major elements of this detector upgrade are the…
Pixel Detectors, as the current technology of choice for the innermost vertex detection, have reached a stage at which large detectors have been built for the LHC experiments and a new era of developments, both for hybrid and for monolithic…
The two-dimensional interpolating readout concept of the Virtual-Pixel detector (ViP detector) goes along with an enormous reduction of electronic channels compared to pure pixel devices. However, the special concept of the readout…
We in the physics community expect the LHC to uncover new physics in the next few years. The character and energy scale of the new physics remain unclear, but it is likely that data from the LHC will need to be complemented by information…
The CMS-TOTEM Precision Proton Spectrometer (CT-PPS) is an approved project to add tracking and timing information at approximately $\pm$210~m from the interaction point around the CMS detector. It is designed to operate at high luminosity…
We report recent developments and tests with beams and cosmic rays of the gaseous photomultiplier (GasPM). The GasPM is a photosensor that combines a photocathode with the avalanche-multiplication mechanism of a resistive-plate chamber,…
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the…
The ATLAS experiment pixel detector upgrade plans are focused on development of new technology, including the FE-I4 readout integrated circuit. The first upgrade project to make use of this new technology is an "Insertable B-Layer" (IBL)…
Single photon sensitive detectors used in high energy physics are, in some applications, required to cover areas the size of several m2, and more specifically in very strong demand with15 an ever finer imaging and timing capability for…
We present the two kinds of experimental results. One is a continuous variable dense coding experiment, and the other is a photon number detector with high linearity response, the so called charge integration photon detector (CIPD). They…
In order to fully exploit the physics potential of the future high energy e+e- linear collider, a Vertex Tracker able to provide particle track extrapolation with very high resolution is needed. Hybrid Si pixel sensors are an attractive…
The Belle II experiment, operating at the asymmetric SuperKEKB $e^+e^-$ collider, is preparing an upgrade of its vertex detector to cope with an increased luminosity of $6 \times 10^{35}$ cm$^{-2}$s$^{-1}$. The upgraded vertex detector…
A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…
The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5$\times10^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000-4000…
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $\eta$ region. To improve both the tracking and…
The Micro Vertex Detector (MVD) of the future Compressed Baryonic Matter (CBM) experiment at FAIR will have to provide a spatial precision of $\sim 5~\rm \mu m$ in combination with a material budget of 0.3\% - 0.5\% X$_0$ for a full…
The 4th Concept detector presently being designed for the International Linear Collider introduces several innovations in order to achieve the necessary experimental goal of a detecter that is 2-to-10 times better than the already excellent…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the…
We present new developments, based on beam tests and cosmic rays, on the gaseous photomultiplier (GasPM). The GasPM detects photons by combining a photocathode with a resistive-plate-chamber avalanche. It achieves $\mathcal{O}$(10) ps time…